| 注册
首页|期刊导航|电力工程技术|基于S11和S21互比对的GIS局部放电特高频传感器校验仿真

基于S11和S21互比对的GIS局部放电特高频传感器校验仿真

王路伽 房春旭 杨海涛 吴兴旺 胡啸宇 吴杰

电力工程技术2026,Vol.45Issue(3):28-36,9.
电力工程技术2026,Vol.45Issue(3):28-36,9.DOI:10.12158/j.2096-3203.2026.03.004

基于S11和S21互比对的GIS局部放电特高频传感器校验仿真

Simulation of GIS partial discharge UHF sensor verification based on S11 and S21 cross-comparison

王路伽 1房春旭 1杨海涛 2吴兴旺 2胡啸宇 2吴杰2

作者信息

  • 1. 中国矿业大学电气工程学院,江苏 徐州 221018
  • 2. 国网安徽省电力有限公司电力科学研究院,安徽 合肥 230601
  • 折叠

摘要

Abstract

Ultra-high frequency(UHF)detection method is highly accurate and has fault localization function.At present,most gas-insulated switchgear(GIS)systems are equipped with online UHF monitoring devices to detect partial discharges.In order to ensure the accuracy of the detection results,UHF sensors need to be verified regularly.UHF sensors used for on-line monitoring are usually installed at the handholes of the GIS and cannot be removed.Measuring laboratory verification indexes(e.g.equivalent height,dynamic range,etc.)of the sensors directly is very difficult.However,it is easier to measure S11 of the sensor to be verified and S21 between it and the neighboring sensors by injecting power signals.Accordingly,this paper presents a simulation study of the GIS partial discharge UHF sensor verification method based on the joint cross-comparison of S11 and S21.Firstly,the equivalent S-parameter network and the change characteristics of S11 and S21 during the verification of GIS UHF sensors are analyzed.Secondly,UHF sensors and degraded sensors caused by typical factors are modelled.Finally,the above sensors are coupled in the handholes of different structural GIS according to the actual situation.The S11 and S21 curves of various types of sensors are simulated and the accuracy of the simulation models are verified by experiments.Analyzing the results of this simulation model,S11 is mainly related to the sensor performance and the handhole;S21 is mainly related to the sensor performance and the GIS structure.Therefore,S11 and S21 can be used as indicators for on-site verification of GIS UHF sensors.Then,the performance of the sensors can be effectively verified by cross-comparing S11 and S21 at corresponding positions across different phases of GIS.

关键词

气体绝缘组合电器(GIS)/局部放电/校验/特高频传感器/S11/S21/互比对

Key words

gas-insulated switchgear(GIS)/partial discharge/verification/ultra-high frequency(UHF)sensor/S11/S21/cross-comparison

分类

信息技术与安全科学

引用本文复制引用

王路伽,房春旭,杨海涛,吴兴旺,胡啸宇,吴杰..基于S11和S21互比对的GIS局部放电特高频传感器校验仿真[J].电力工程技术,2026,45(3):28-36,9.