| 注册
首页|期刊导航|煤气与热力|严寒地区被动房室内PM2.5质量平衡模型与分析

严寒地区被动房室内PM2.5质量平衡模型与分析

余志义 王昭俊 关迪午 薛庆雯

煤气与热力2026,Vol.46Issue(3):31-37,7.
煤气与热力2026,Vol.46Issue(3):31-37,7.

严寒地区被动房室内PM2.5质量平衡模型与分析

Mass Balance Model and Analysis of Indoor PM2.5 in Passive Houses in Severely Cold Regions

余志义 1王昭俊 1关迪午 1薛庆雯1

作者信息

  • 1. 哈尔滨工业大学 建筑与设计学院,黑龙江 哈尔滨 150006||寒地城乡人居环境科学与技术工业和信息化部重点实验室,黑龙江哈尔滨 150090
  • 折叠

摘要

Abstract

The lumped parameter method was adopted to establish a mass balance model for indoor PM2.5 in passive houses.Two typical passive houses in severely cold regions were selected as study subjects.Through on-site measurements including the CO2 decay method and continuous monitoring,model parameters(air ex-change rate,characteristic parameters of the fresh air system,PM2.5 deposition rate,PM2.5 penetration coef-ficient,and source strength)were determined.The re-lationship between the characteristic parameters of the fresh air system and outdoor PM2.5 mass concentration was established.The penetration coefficients and depo-sition rates of the two passive houses are relatively close,with an average indoor PM2.5 deposition rate of 0.02 h-1 and an average penetration coefficient of 0.30,both lower than those of conventional houses and previ-ous test results.The measured value of the characteris-tic parameter of the fresh air system is 1.30±0.12,indi-cating that the existing M5 medium-efficiency filters cannot effectively intercept PM2.5.The established in-door PM2.5 mass balance model and the key param-eters obtained from field measurements are reasonable.

关键词

被动房/细颗粒物(PM2.5)/穿透系数/渗透因子/沉降率/严寒地区

Key words

passive house/fine particulate matter(PM2.5)/penetration coefficient/infiltration factor/de-position rate/severely cold region

分类

建筑与水利

引用本文复制引用

余志义,王昭俊,关迪午,薛庆雯..严寒地区被动房室内PM2.5质量平衡模型与分析[J].煤气与热力,2026,46(3):31-37,7.

基金项目

国家自然科学基金项目(项目编号:51678179) (项目编号:51678179)

煤气与热力

1000-4416

访问量0
|
下载量0