摘要
Abstract
In order to reveal the thermal imbalance characteristics of the ground source heat pump system in hot summer and cold winter areas,this paper obtains the performance parameters of the system through numerical simulation over 10-years period of continuous opera-tion.Subsequently,a multi-objective optimization genetic algorithm was employed to integrate the system energy efficiency,thermal imbalance indicator underground and the source/end load imbalance rate,thus obtaining the optimal operating conditions.The findings indicate that during a single cooling or heating season,the borehole heat exchangers experience considerable heat and cold accumulation,accompanied by a gradual decline in heat transfer performance and a notable imbalance between the source and end load.Through optimal control,energy efficiency of the system is markedly enhanced.Furthermore,the thermal imbalance condition underground is improved.Additionally,the equipment of the composite geothermal heat pump system can be switched on and off adaptively,and the imbalance rate between the source/end load can be controlled to be less than 25%,thereby achieving on-demand cooling or heating supply.The findings of this study have the potential to promote the application of ground source heat pump in hot summer and cold winter regions.关键词
地源热泵/热平衡指数/负荷不平衡率/最优运行Key words
ground source heat pump/thermal balance index/load imbalance rate/optimal operation分类
能源科技引用本文复制引用
饶大骞,闫亚蕾,王合安,高斌,高文龙,朱波,赵亚洲..夏热冬冷地区地源热泵系统冷热不平衡特性及优化运行策略研究[J].可再生能源,2026,44(3):319-328,10.基金项目
国家自然科学基金项目(52376017) (52376017)
浙江大学实验技术研究项目(SYBJS202306). (SYBJS202306)