Existing intelligent fault diagnosis techniques exhibit poor precision,low recall,slow inference speed in equipment identification and segmentation,and low diagnostic efficiency in fault diagnosis as well as cannot diagnose and analyze specific equipment categories.To overcome these drawbacks,in this study,we perform infrared fault diagnosis of substation equipment using the self-diagnosis method of segmentation before diagnosis.An efficient ViT network with faster reasoning speed is used to improve instance segmentation.The transformer cascade structure in the backbone is improved to increase the sensitivity of the network to weak targets,and the improved SK attention method is added to increase the network's interest in the substation equipment.The GD mechanism is used in the neck to improve the model's ability to use features of different sizes,and the optimized mask loss function is used in the head to improve the model's ability to diagnose infrared faults in substation equipment.The loss function improves the segmentation ability of the model at the boundary of the substation equipment,providing accurate segmentation regions for subsequent fault diagnosis.In terms of fault diagnosis,the relative temperature difference in the area is used for fault self-diagnosis in the segmented equipment region.The experimental results show that the performance of the improved network improves the detection and segmentation mAP values on the test set by 8.4%and 6.0%,respectively,although a slight decrease in the inference speed is observed.In addition,a fault diagnosis accuracy of up to 91.3%is obtained.

关键词

变电设备/红外故障诊断/实例分割/面域相对温差

Key words

substation equipment/infrared fault diagnosis/instance segmentation/area relative temperature difference

分类

信息技术与安全科学

引用本文复制引用

黄光攀,张林鍹,张子豪,陈飞,郑兴..基于改进Efficient ViT与面域相对温差法的变电设备红外故障诊断[J].红外技术,2026,48(3):362-371,10.

基金项目

新疆维吾尔自治区自然科学基金项目(2022D01C431). (2022D01C431)

红外技术

1001-8891

访问量1
|
下载量0
段落导航相关论文