| 注册
首页|期刊导航|汕头大学医学院学报|基于磁共振波谱测温的C6胶质瘤大鼠脑温度梯度研究

基于磁共振波谱测温的C6胶质瘤大鼠脑温度梯度研究

林枫枫 郑欣慧 张晓磊 甘浩川 孔令梅 吴仁华

汕头大学医学院学报2026,Vol.39Issue(1):1-6,6.
汕头大学医学院学报2026,Vol.39Issue(1):1-6,6.DOI:10.13401/j.cnki.jsumc.2026.01.001

基于磁共振波谱测温的C6胶质瘤大鼠脑温度梯度研究

Study on brain temperature gradient in C6 glioma rats based on magnetic resonance spectroscopy thermometry

林枫枫 1郑欣慧 1张晓磊 1甘浩川 1孔令梅 2吴仁华1

作者信息

  • 1. 汕头大学医学院第二附属医院医学影像科,广东 汕头 515041
  • 2. 汕头大学精神卫生中心医学影像科,广东 汕头 515041
  • 折叠

摘要

Abstract

Objective:To investigate the spatial distribution characteristics of brain temperature in a rat C6 glioma model and its value in defining the tumor infiltration boundary.Methods:Sixteen Sprague-Dawley(SD)rats were randomly divided into a glioma group(n=8)and a control group(n=8).The glioma group underwent stereotactic injection of C6 glioma cells into the right caudate nucleus,while the control group received an equal volume of culture medium.On the 14th day post-injection,all rats underwent conventional MRI and proton magnetic resonance spectroscopy(1H-MRS)on a 7T MRI scanner.Spectra were acquired from the tumor solid part,peritumoral area,and contralateral normal caudate nucleus(symmetric bilateral locations for the control group).Absolute brain temperature for each volume of interest(VOI)was calculated using an in vitro temperature calibration model.Results:In glioma-bearing rats,brain temperature differed significantly among the various brain regions(F=37.05,P<0.01).The temperature was highest in the tumor solid part(38.53±0.24℃),which was significantly higher than that in the peritumoral area(38.14±0.18℃,P<0.01)and the contralateral normal brain area(37.63±0.19℃,P<0.01).The temperature in the peritumoral area was also significantly higher than that in the contralateral normal brain area(P<0.01).In the control group,there was no significant temperature difference between the bilateral brain regions(P>0.05).The temperature in the contralateral normal brain area of the glioma group was significantly higher than that in the corresponding brain area of the control group(P<0.01).Conclusion:MRS thermometry can sensitively detect brain temperature gradients in the C6 glioma model.The elevated temperature in the peritumoral area provides a potential biomarker for identifying the tumor infiltration boundary.

关键词

磁共振波谱/脑温/胶质瘤/C6大鼠模型/肿瘤边界

Key words

magnetic resonance spectroscopy/brain temperature/glioma/C6 rat model/tumor boundary

分类

医药卫生

引用本文复制引用

林枫枫,郑欣慧,张晓磊,甘浩川,孔令梅,吴仁华..基于磁共振波谱测温的C6胶质瘤大鼠脑温度梯度研究[J].汕头大学医学院学报,2026,39(1):1-6,6.

基金项目

国家自然科学基金(82471974) (82471974)

汕头大学医学院学报

1007-4716

访问量0
|
下载量0
段落导航相关论文