| 注册
首页|期刊导航|现代电子技术|基于阀侧电流不对称性的LCC-HVDC系统换相失败检测

基于阀侧电流不对称性的LCC-HVDC系统换相失败检测

刘洁彤 刘对 林兵 陈曦 何志杰 卢宇

现代电子技术2026,Vol.49Issue(6):152-159,167,9.
现代电子技术2026,Vol.49Issue(6):152-159,167,9.DOI:10.16652/j.issn.1004-373x.2026.06.023

基于阀侧电流不对称性的LCC-HVDC系统换相失败检测

Detection of commutation failure in LCC-HVDC system based on the current asymmetry of valve-side

刘洁彤 1刘对 2林兵 1陈曦 1何志杰 1卢宇1

作者信息

  • 1. 福建师范大学 物理与能源学院,福建 福州 350117
  • 2. 福建师范大学 物理与能源学院,福建 福州 350117||明珠电气股份有限公司,广东 广州 511468||福州大学 电气工程与自动化学院,福建 福州 350108
  • 折叠

摘要

Abstract

With the widespread application of HVDC transmission technology in long-distance and large-capacity power transmission,line-commutated converter based high voltage direct current(LCC-HVDC)attracts much attention due to its unique advantages.However,the semi-controlled devices used in LCC-HVDC system lack self turning off capability,and commutation failure is easy to occur in case of fault,which greatly affects the stability and safety of the system.Therefore,the dynamic commutation process of LCC-HVDC system is researched,the variation characteristics of the valve-side current of the converter transformer under normal operation and AC system faults are analyzed in detail,and the variation features of this current are extracted.On this basis,a commutation failure criterion of LCC-HVDC system is proposed based on its asymmetry characteristics,enabling rapid and accurate identification of multiple commutation failures.Based on the PSCAD/EMTDC simulation platform,the effectiveness of this method under various operating conditions is verified by means of simulation models of CIGRE LCC-HVDC system and practical double-circuit transmission lines models on the same tower.The experimental results indicate that the proposed criterion has fast response and high detection accuracy in multi-commutation failure scenarios,demonstrating strong reliability and robustness,and providing a theoretical reference for the detection of commutation failure in practical engineering applications.

关键词

换相失败检测/LCC-HVDC系统/换流变压器/阀侧电流/不对称性/换相失败判据/CIGRE标准测试模型

Key words

commutation failure detection/LCC-HVDC system/converter transformer/valve-side current/asymmetry/commutation failure criterion/CIGRE standard test model

分类

信息技术与安全科学

引用本文复制引用

刘洁彤,刘对,林兵,陈曦,何志杰,卢宇..基于阀侧电流不对称性的LCC-HVDC系统换相失败检测[J].现代电子技术,2026,49(6):152-159,167,9.

基金项目

福建省中青年教师教育科研项目(科技类)(JAT231017) (科技类)

福建省高校产学合作项目(2022H6024) (2022H6024)

福建省科技厅引导项目(2023H0009) (2023H0009)

福建省自然科学基金项目(2025J08144) (2025J08144)

现代电子技术

1004-373X

访问量0
|
下载量0
段落导航相关论文