In view of the objetive limitation of sample data acquisition during the debugging process of secondary e-quipment in substations.It is difficult to analyze and judge the reliability of the system based on small-size sample data.This paper studies the reliability analysis method of secondary equipment based on Bootstrap method for sam-ple expansion.Firstly,parameter distribution estimation based on Bootstrap method is discussed.Then,a Boot-strap sample expansion method that combines empirical information and sample structure transformation is proposed to overcome the problem of concentrated sample data and limited information coverage in classic Bootstrap method.On the basis of parameter distribution estimation,the reliability of secondary equipment is analyzed based on the probability distribution of the operating threshold.Finally,the effectiveness of the proposed method is verified through simulation experiments.

关键词

变电站/二次设备/可靠性分析/参数分布估计

Key words

substation/secondary equipment/reliability analysis/parameter distribution estimation

分类

信息技术与安全科学

引用本文复制引用

晁武杰,唐志军,梁懿..基于智能变电站二次设备联调小样本的系统可靠性分析方法研究[J].电测与仪表,2026,63(4):112-119,8.

基金项目

国网福建省电力有限公司科技项目(52130415003V) (52130415003V)

电测与仪表

1001-1390

访问量0
|
下载量0
段落导航相关论文