| 注册
首页|期刊导航|电力系统保护与控制|基于主动探测式的双端弱馈交流系统模型识别纵联保护

基于主动探测式的双端弱馈交流系统模型识别纵联保护

张卓凡 侯俊杰 樊艳芳 宋国兵 吴小芳 张常健

电力系统保护与控制2026,Vol.54Issue(9):26-38,13.
电力系统保护与控制2026,Vol.54Issue(9):26-38,13.DOI:10.19783/j.cnki.pspc.250935

基于主动探测式的双端弱馈交流系统模型识别纵联保护

Model identification pilot protection of dual-end weak-feed AC systems based on active detection

张卓凡 1侯俊杰 1樊艳芳 1宋国兵 2吴小芳 3张常健1

作者信息

  • 1. 新疆大学电气工程学院,新疆 乌鲁木齐 830046
  • 2. 新疆大学电气工程学院,新疆 乌鲁木齐 830046||西安交通大学电气工程学院,陕西 西安 711049
  • 3. 国网新疆电力有限公司电力科学研究院,新疆 乌鲁木齐 830011
  • 折叠

摘要

Abstract

The integration of renewable energy via flexible DC transmission systems has become an important development direction for enabling large-scale renewable energy grid connection.The power supply characteristics of dual-end weak-feed AC systems differ significantly from those of traditional synchronous generator-based systems.Moreover,the converter stations operate in rectifier and inverter modes,leading to uncertainty in the direction of fault currents.This poses adaptability challenges for conventional model identification-based pilot protection schemes.To address these issues,a model identification pilot protection scheme for dual-end weak-feed AC systems based on active detection is proposed.First,the applicability of conventional model identification-based pilot protection in such systems is studied.On this basis,considering the concept of coordinated control and protection,and leveraging the high controllability of converter stations,a control strategy is proposed in which a characteristic frequency signal is superimposed and injected into the differential-mode component.The phase difference characteristics of the line model under the injection characteristic frequency signal are then analyzed.Finally,by combining a fault detection initiation criterion and a main fault identification criterion,a model identification pilot protection scheme that is independent of operating modes is constructed.Simulation results verify the effectiveness of the proposed scheme.The results show that the thresholds of the proposed protection scheme do not require simulation-based tuning and are not dependent on the accuracy of parameter calculation.The scheme can reliably identify internal and external faults,withstand transition resistances up to 300 Ω and noise interference of 25 dB,and is suitable for double-ended weak-feed AC systems.

关键词

双端弱馈交流系统/主动注入控制策略/模型识别/纵联保护

Key words

dual-end weak-feed AC system/active injection control strategy/model identification/pilot protection

引用本文复制引用

张卓凡,侯俊杰,樊艳芳,宋国兵,吴小芳,张常健..基于主动探测式的双端弱馈交流系统模型识别纵联保护[J].电力系统保护与控制,2026,54(9):26-38,13.

基金项目

This work is supported by the National Natural Science Foundation of China(No.52567016 and No.52442705). 国家自然科学基金项目资助(52567016,52442705) (No.52567016 and No.52442705)

新疆维吾尔自治区自然科学基金项目资助(2022D01C662) (2022D01C662)

国家重点研发计划项目资助(2021YFB1507000):"天池英才引进"计划项目资助 (2021YFB1507000)

电力系统保护与控制

1674-3415

访问量0
|
下载量0
段落导航相关论文