计算机与数字工程2026,Vol.54Issue(2):342-347,6.DOI:10.3969/j.issn.1672-9722.2026.02.008
一种基于MLS算法的屏下压感校准方法
A Method for Under-screen Pressure Sensitivity Calibration Based on MLS Algorithm
高晓盘 1慕少宁 1孙君鹏 1王利平 1周宇星1
作者信息
- 1. 联想(北京)有限公司 北京 100085
- 折叠
摘要
Abstract
In the process of pressure sensitivity test and calibration under the screen of mobile handheld terminal equipment(mobile phones,tablets),due to the limitation of the structure of the test module itself,variations of the pressure of all the coordi-nate positions to be calibrated cannot be collected.During the actual test,according to the change of the coordinates of the dotted po-sition of the module,the calibration system needs to match the calibration coefficients of the same position to obtain the test pressure value through calculation.This paper proposes a new solution for pressure-sensing detection under large-area screen.Based on the MLS(Moving Least Squares)algorithm,the irregular surface constructed by variations of the pressure of the node coordinate posi-tion collected by the module is used for surface fitting to obtain variations of the pressure at the full screen coordinate position.The optimal selection of the influence radius and weight function in the algorithm is determined through numerical experiments.The nu-merical experiment results meet the calibration accuracy requirements and realize the full-screen pressure-sensing calibration.关键词
压感/校准系数/MLS算法/拟合/影响半径Key words
pressure sensitivity/calibration coefficients/MLS algorithm/fitting/influence radius分类
信息技术与安全科学引用本文复制引用
高晓盘,慕少宁,孙君鹏,王利平,周宇星..一种基于MLS算法的屏下压感校准方法[J].计算机与数字工程,2026,54(2):342-347,6.