云南水力发电2026,Vol.42Issue(4):77-79,3.DOI:10.3969/j.issn.1006-3951.2026.04.019
某水电站4号机筒阀动作过程异常振动分析与处理
Analysis and Treatment of Abnormal Vibration During the Operation of the No.4 Turbine Cylinder Valve in a Hydropower Station
张黎 1曹泽昊 1李旭明 1刘烜 1林建雄1
作者信息
- 1. 雅砻江流域水电开发有限公司,四川 成都 610051
- 折叠
摘要
Abstract
After the oil pressure drop rate of the cylinder valve pressure oil tank in a certain hydropower station significantly increased,abnormal vibration occurred during the treatment process.By replacing the encoder of the cylinder valve opening and zeroing the stroke of the cylinder valve relay,it was found that the electrical zero drift and inaccurate zeroing method of the cylinder valve relay were the reasons for the significantly faster oil pressure drop rate and abnormal vibration.Finally,the zero position adjustment was carried out by rotating the digital cylinder in the direction of cylinder valve closure to make the cylinder valve of Unit 4 operate normally.关键词
水电站/水轮发电机/筒阀接力器/振动/原因分析Key words
hydropower station/water turbine generator/cylinder valve relay/vibration/cause analysis分类
能源科技引用本文复制引用