Objective:To compare the acquisition time and image quality of three diffusion-weighted imaging(DWI)sequences,including single-shot diffusion-weighted imaging(SS-DWI),readout segmentation of long variable echo-trains diffusion-weighted imaging(Resolve-DWI),and Resolve-DWI with simultaneous multi-slice(SMS-Resolve-DWI),in MRI examinations of acute cerebral infarction,with the aimof providing evidence for optimizing clinical scanning protocols.Materials and Methods:Eighty-four patients with acute cerebral infarction treated at our hospital from July 2023 to December 2024 were retrospectively enrolled.Each patient underwent sequential scanning with conventional SS-DWI,Resolve-DWI,and SMS-Resolve-DWI.Two senior radiologists independently and blindly evaluated the image quality using a 5-point Likert scale.Objective metrics included signal intensity(SI),apparent diffusion coefficient(ADC),signal-to-noise ratio(SNR),contrast ratio(CR),contrast-to-noise ratio(CNR),and SNR efficiency.Statistical analysis was performed using SPSS 26.0.The normality of continuous variables was assessed by the Shapiro-Wilk test.Data with normal distributions were expressed as mean±standard deviation,and those without were represented as median(interquartile range).One-way analysis of variance(ANOVA)or the Kruskal-Wallis H test was used for group comparisons.Interobserver agreement was assessed with weighted Kappa statistics.Results:The scan times were 1 min 57 s for SS-DWI,5 min 21 s for Resolve-DWI,and 3 min 16 s for SMS-Resolve-DWI.Subjective scoring demonstrated good to excellent inter-rater agreement(Kappa values 0.630 to 0.982).In terms of image quality scores,both SMS-Resolve-DWI and Resolve-DWI showed significantly higher scores than SS-DWI(P<0.05),with no significant difference between the two advanced sequences(median Likert score of both was 4).Regarding objective metrics,there were no significant differences in ADC values among the three sequences(P>0.05).Compared to SS-DWI,both Resolve-DWI and SMS-Resolve-DWI showed higher SI(in both lesion and contralateral brain tissue),SNR,and CNR(P<0.001),with no significant difference between the two advanced sequences(P>0.05).The CR of SS-DWI was higher than that of SMS-Resolve-DWI(P=0.013).The SNR efficiency of SS-DWI and SMS-Resolve-DWI was superior to that of Resolve-DWI(P<0.001),with no significant difference between SS-DWI and SMS-Resolve-DWI(P>0.05).Conclusions:SMS-Resolve-DWI combines the scanning efficiency of SS-DWI with the image quality of Resolve-DWI,while maintaining the accuracy of ADC quantification.It can be recommended as the preferred MRI protocol for acute cerebral infarction examination.关键词
急性脑梗死/磁共振成像/扩散加权成像/分段读出/同时多层采集/图像质量Key words
acute cerebral infarction/magnetic resonance imaging/diffusion-weighted imaging/readout segmentation of long variable echo-trains/simultaneous multi-slice/image quality分类
医药卫生引用本文复制引用
李霆,卢远源,李传,赖茵圻,冯汝静,梁秀群,孙振萌,黄炎,邓德茂..三种不同扩散成像序列在急性脑梗死检查中的用时及图像质量对比研究[J].磁共振成像,2026,17(4):88-94,7.基金项目
广西壮族自治区卫生健康委员会自筹经费科研课题项目(编号:Z-A20230031)Guangxi Zhuang Autonomous Region Health Commission Self-Funded Scientific Research Project(No.Z-A20230031). (编号:Z-A20230031)