| 注册
首页|期刊导航|电工技术学报|嵌入式同塔三回直流系统多重相模变换及其在故障选线中的应用

嵌入式同塔三回直流系统多重相模变换及其在故障选线中的应用

李振兴 安喆 朱益 孔祥平 翁汉琍

电工技术学报2026,Vol.41Issue(9):3100-3114,15.
电工技术学报2026,Vol.41Issue(9):3100-3114,15.DOI:10.19595/j.cnki.1000-6753.tces.250692

嵌入式同塔三回直流系统多重相模变换及其在故障选线中的应用

Multiple Phase-Mode Transformation of Embedded Co-Tower Three-Circuit DC System and Its Application to Fault Line Selection

李振兴 1安喆 2朱益 2孔祥平 3翁汉琍1

作者信息

  • 1. 三峡大学电气与新能源学院 宜昌 443002||新能源微电网湖北省协同创新中心(三峡大学) 宜昌 443002
  • 2. 三峡大学电气与新能源学院 宜昌 443002
  • 3. 国网江苏省电力有限公司电力科学研究院 南京 211103
  • 折叠

摘要

Abstract

Embedded high voltage direct current system is an effective solution to enhance the regional power grid's power transfer and dissipation capacity.To effectively utilize the transmission corridor,some projects have transformed the double-circuit AC transmission line on the same tower into three bipolar DC transmission systems.The formed embedded co-tower three-circuit DC system has more complex coupling characteristics and richer fault types.Faults on any line can lead to voltage and current fluctuations on non-faulted lines,which can seriously impact the fault localization of DC lines.However,the existing decoupling schemes cannot realize the effective decoupling of this system,and cannot ensure the regularity and easy recognition of the fault characteristics after decoupling.To address these issues,this paper proposes a faulty line identification scheme based on multiple phase-mode transformation. The coupling characteristics of the embedded co-tower three-circuit DC system are analyzed.The impedance matrix is constructed by considering the effects of layer height and symmetrical line arrangement.A decoupling method based on multiple phase-mode transformation is proposed,which combines the accurate identification of faulty circuits and the effective decoupling of faulty lines;Aiming at the fault voltage mutation features,the polarity features that are more clear,easy to recognize and have significant differences are extracted,and then a fault line identification scheme based on the modulus polarity combination is proposed.Finally,the performance of the proposed protection scheme is verified by constructing a model of the embedded co-tower three-circuit DC system in PSCAD,and the simulation results show that the proposed scheme is able to identify all fault types accurately,and still has excellent results even under high-resistance fault conditions. The following conclusions can be drawn from the simulation analysis:(1)The proposed incomplete decoupling method for the embedded co-tower three-circuit DC system is adaptable and has a simple decoupling matrix structure,which significantly reduces the computational difficulty compared to the traditional decoupling scheme.(2)Applying the proposed decoupling scheme,a faulty line identification scheme based on modulus polarity combination is proposed.The fault characteristics of the system are significant during failure,which significantly reduces the complexity and workload of faulty line identification compared with the traditional analysis methods.(3)The proposed fault type prediction method based on multiple phase-mode transformation of fault components can effectively address the problem of overlapping polarity combinations,and has strong capacity of withstanding transition resistance and anti-interference performance.

关键词

嵌入式同塔三回直流系统/多重相模变换/电压突变量/极性组合重叠

Key words

Embedded co-tower three-circuit DC system/multiple phase-mode transformation/voltage mutation/overlapping polarity combination

分类

信息技术与安全科学

引用本文复制引用

李振兴,安喆,朱益,孔祥平,翁汉琍..嵌入式同塔三回直流系统多重相模变换及其在故障选线中的应用[J].电工技术学报,2026,41(9):3100-3114,15.

基金项目

国家自然科学基金资助项目(52077120). (52077120)

电工技术学报

1000-6753

访问量1
|
下载量0