| 注册
首页|期刊导航|四川水力发电|某水电站机组水导瓦温升高原因分析及处理

某水电站机组水导瓦温升高原因分析及处理

何勇 王文超

四川水力发电2026,Vol.45Issue(2):90-95,6.
四川水力发电2026,Vol.45Issue(2):90-95,6.DOI:10.20196/j.cnki.scslfd.20260219

某水电站机组水导瓦温升高原因分析及处理

Analysis and treatment of temperature rise in turbine guide bearings of the units of a hydropower project

何勇 1王文超1

作者信息

  • 1. 雅砻江流域水电开发有限公司,四川 成都 610051
  • 折叠

摘要

Abstract

By analysing the phenomenon of temperature rising in the turbine guide bearings of the units of a hy-dropower project,it was concluded that the temperature rise in the guide bearings was caused by two factors:deformation of the guide bearing support during the replacement of the guide bearing cooler,which led to a re-duction in the clearance of some guide bearing pads,and an increase in ambient temperature,which provides a-nalysis basis and reference for addressing similar high-temperature issues in guide bearings of the units of a hy-dropower project.

关键词

水导轴承支架发生/变形/水导瓦间隙/环境温度/水导瓦温升高

Key words

the guide bearing support/deformation/guide bearing gaps/environmental temperature/tempera-ture rise in turbine guide bearings