云南冶金2026,Vol.55Issue(2):149-154,158,7.
离子选择电极法测定松香基助焊剂中氟
Determination of Fluoride in Rosin-Based Flux by Ion Selective Electrode Method
摘要
Abstract
An analytical method for the determination of fluoride content in rosin-based flux by ion selective electrode method was established.Experiments were carried out on sample weight,decomposition temperature,solvent dosage,total ionic strength adjuster dosage,electrode stabilization time and interference of common coexisting ions.The results show that the determination range of the method is 0.1%~4.0%,the relative standard deviation(RSD,n=11)is 1.66%~2.08%,and the recovery rates of standard addition are 95.2%~104.0%.The results are consistent with those by ion chromatography,indicating that the method is suitable for the determination of fluoride content in flux.关键词
离子选择电极法/松香基助焊剂/氟含量Key words
ion selective electrode method/rosin-based flux/fluoride content分类
化学化工引用本文复制引用
韩红兰,魏梦霞,李丽,段泽平,黄慧兰,沙文吉,赵中梅..离子选择电极法测定松香基助焊剂中氟[J].云南冶金,2026,55(2):149-154,158,7.基金项目
云南省科技人才与平台计划(202405AK34005) (202405AK34005)