T/CES 267-2023《高压交流断路器潜伏性故障监测装置技术规范》团体标准解读
Interpretation of the Association Standard T/CES 267-2023,Technical specification for latent faults monitoring equipment of high voltage AC circuit breakers
刘怀宇 1陈昊 2胡晓静3
作者信息
- 1. 国网江苏省电力有限公司超高压分公司
- 2. 国网江苏省电力有限公司南京供电分公司
- 3. 许昌开普电气研究院有限公司
- 折叠
摘要
Abstract
The paper aims to help the relevant personnel better understand the association standard T/CES 267-2023,Technical specification for latent faults monitoring equipment of high voltage AC circuit breakers,lay a foundation for the promotion and application of this standard,promote the development of technology in the field of online monitoring of primary power equipment,and fill the gap of relevant standards in the field of online monitoring of latent faults of high voltage circuit breakers in China.This paper provides a detailed interpretation of the standard from the perspectives of the background and significance of the development of the standard,as well as its main technical contents.After the implementation of the standard,it shows outstanding technical advancement and adaptability.The technical indicators fully consider the current technical status and market demands,which can not only promote the improvement of the technical level of production enterprises,but also improve the ability of application enterprises to monitor the status of circuit breakers and give early warning of their faults.关键词
断路器/在线监测/潜伏性故障/传感器/故障诊断Key words