科技创新与应用2026,Vol.16Issue(13):10-13,4.DOI:10.19981/j.CN23-1581/G3.2026.13.003
特殊环形端面焊缝射线检测技术研究
阳雷 1王哲 1杨帆1
作者信息
- 1. 中国核动力研究设计院,成都 610213
- 折叠
摘要
Abstract
During the manufacturing process of large-scale nuclear-level workpieces,an end weld with a special structure will be produced.This weld belongs to a Class I weld.The design technical conditions require radiographic testing of this weld.This research carried out radiographic testing process tests to address the technical problems that conventional radiographic testing methods cannot be implemented due to the limitations of the workpiece structure and space environment during radiographic testing of the weld.Through the γ-ray detection process experiment,the best position of the ray source and the best detection process are found,and the γ-ray detection results at the best position of the ray source and the best detection process state are compared with the conventional X-ray detection results to verify the detection effect of γ-rays.The test results prove that the testing process determined in this study can better solve the technical problems existing in radiographic testing of the weld and lay a technical foundation for ensuring the quality of the weld.关键词
射线检测/灵敏度/几何不清晰度/X射线/γ射线Key words
radiographic testing/sensitivity/geometric ambiguity/X-ray/γ-ray分类
能源科技引用本文复制引用
阳雷,王哲,杨帆..特殊环形端面焊缝射线检测技术研究[J].科技创新与应用,2026,16(13):10-13,4.