基于强迫振荡技术的肺功能测量装置设计

王梦源 刘秉鑫 林俊杰 殷涛 刘志朋 张顺起

医疗卫生装备2026,Vol.47Issue(5):21-28,8.
医疗卫生装备2026,Vol.47Issue(5):21-28,8.DOI:10.19745/j.1003-8868.2026070

基于强迫振荡技术的肺功能测量装置设计

Design of pulmonary function measurement device based on forced oscillation technique

王梦源 1刘秉鑫 1林俊杰 1殷涛 1刘志朋 1张顺起1

作者信息

  • 1. 中国医学科学院生物医学工程研究所,先进医用材料与医疗器械全国重点实验室,天津市神经调控与修复重点实验室,天津医学健康科学研究院,呼吸与危重症诊疗技术与器械教育部工程研究中心,天津 300192
  • 折叠

摘要

Abstract

Objective To design a portable pulmonary function measurement device based on the forced oscillation technique,so as to enable the early diagnosis of chronic obstructive pulmonary disease(COPD)and improve patient comfort and device portability.Methods The portable pulmonary function measurement device had its housing made of acrylonitrile-butadiene styrene(ABS)engineering plastic and a STM32F103 as the main control chip,which was composed of a sensor acquisition module,an oscillation module and a power supply module.The sensor acquisition module consisted of two SM7391 digital differential pressure sensors;the oscillation module primarily comprised a waveform generation unit,a signal rectification circuit and a power amplification circuit,with a speaker serving as the core executive component;the power supply module was powered by a 24 V DC power adapter and incorporated a power management circuit centered around the TPS54560 chip.The software of the device was divided into a lower embedded system component and a host-based application component.The lower embedded system was programmed using the C programming language under the Keil μVision development environment,and the host-based application component was developed using the App Designer module on the MATLAB platform.To verify the accuracy of the device's pulmonary function measurements,it underwent comparison with a standard commercial clinical spirometer and analysis by Bland-Altman plots and linear regression.Results Bland-Altman and linear regression analyses indicated that the core respiratory impedance parameters measured by this device showed a high degree of agreement with those from the clinical spirometer,thereby meeting clinical requirements for accuracy in airway impedance assessment.Conclusion The pulmonary function measurement device based on the forced oscillation technique accurately measures pulmonary function parameters such as respiratory resistance,reactance,resonance frequency and reactance area,providing reliable technical support for the early diagnosis and dynamic monitoring of respiratory diseases.[Chinese Medical Equipment Journal,2026,47(5):21-28]

关键词

肺功能检测/肺功能测量装置/强迫振荡技术/慢性阻塞性肺疾病/便携医疗设备

Key words

pulmonary function measurement/pulmonary function measurement device/forced oscillation technique/chronic obstructive pulmonary disease/portable medical device

分类

医药卫生

引用本文复制引用

王梦源,刘秉鑫,林俊杰,殷涛,刘志朋,张顺起..基于强迫振荡技术的肺功能测量装置设计[J].医疗卫生装备,2026,47(5):21-28,8.

基金项目

国家重大科研仪器研制项目(81927806) (81927806)

中国医学科学院医学健康前沿交叉研究专项(2023-I2M-QJ-017) (2023-I2M-QJ-017)

天津市自然科学基金项目(24JCYBJC00570) (24JCYBJC00570)

北京协和医学院中央高校基本科研业务费专项资金资助项目(3332025197) (3332025197)

中国博士后科学基金会博士后资助项目(GZC20251897,2025M772880) (GZC20251897,2025M772880)

医疗卫生装备

1003-8868

访问量0
|
下载量0
段落导航相关论文