| 注册
首页|期刊导航|中国医学科学院学报|双层探测器光谱CT定量增强参数评估肝功能储备

双层探测器光谱CT定量增强参数评估肝功能储备

刘梦琦 田亚忠 陈志晔

中国医学科学院学报2026,Vol.48Issue(2):238-243,6.
中国医学科学院学报2026,Vol.48Issue(2):238-243,6.DOI:10.3881/j.issn.1000-503X.16626

双层探测器光谱CT定量增强参数评估肝功能储备

Quantitative Enhancement Parameters of Dual-Layer Detector Spectral CT in the Assessment of Hepatic Functional Reserve

刘梦琦 1田亚忠 1陈志晔1

作者信息

  • 1. 中国人民解放军总医院海南医院放射诊断科,海南 三亚 572013
  • 折叠

摘要

Abstract

Objective To evaluate the value of dual-layer spectral CT-derived iodine concentration(IC)and extracellular volume(ECV)in the portal venous phase in assessing hepatic functional reserve.Methods A total of 24 patients who underwent triphasic abdominal spectral CT enhancement scanning between January 2020 and August 2022 were retrospectively enrolled.IC and ECV maps were generated from spectral base data of the portal venous phase,and IC and ECV values were measured in the left lobe,right lobe,and caudate lobe of the liver.Differences in parameters among hepatic lobes were compared by the Kruskal-Wallis test.Pearson or Spearman correlation analysis was performed to assess the relationships of IC and ECV with parameters of the indocyanine green(ICG)clearance test.The key parameters analyzed included the ICG retention rates at 5 min(ICGR5),at 10 min(ICGR10),at 15 min(ICGR15),and the ICG clearance rate(ICG-CR).On the basis of correlation results,multivariate linear regression models were constructed.Results ECV in the right hepatic lobe showed neg-ative correlations with ICGR5(r=-0.48,P=0.019),ICGR10(r=-0.48,P=0.019),and ICGR15(r=-0.47,P=0.021)and a positive correlation with ICG-CR(r=0.48,P=0.019).IC in the right hepatic lobe also showed negative correlations with ICGR5(r=-0.52,P=0.009),ICGR10(r=-0.52,P=0.009),and ICGR15(r=-0.53,P=0.008)and a positive correlation with ICG-CR(r=0.52,P=0.009).IC in the right hepatic lobe demonstrated the best predictive performance for ICGR5(y=0.62-0.16×IC,R2=0.26,P=0.011)and ICG-CR(y=0.09-0.07×IC,R2=0.32,P=0.004),whereas ECV was not selected in the multivariate regression model.Conclusion The dual-layer spectral CT-derived IC in the portal venous phase of the right hepatic lobe demonstrates significant clinical relevance with hepatic functional reserve,potentially ser-ving as a non-invasive imaging biomarker for liver function assessment.

关键词

肝功能储备/光谱CT/碘浓度/细胞外容积/吲哚菁绿清除试验

Key words

hepatic functional reserve/spectral CT/iodine concentration/extracellular volume/indocy-anine green clearance test

分类

医药卫生

引用本文复制引用

刘梦琦,田亚忠,陈志晔..双层探测器光谱CT定量增强参数评估肝功能储备[J].中国医学科学院学报,2026,48(2):238-243,6.

基金项目

国家重点研发计划(2023YFF1204104) (2023YFF1204104)

中国医学科学院学报

1000-503X

访问量0
|
下载量0
段落导航相关论文