夏热冬暖地区蒸发式全热回收新风机组设计能效计算方法探讨

Energy-Saving Evaluation Method and Calculation Discussion of Evaporative Total Heat Recovery Fresh Air Units in Hot-Summer and Warm-Winter Regions

龚思越 1郭勇 1江宋标1

作者信息

  • 1. 广东省建筑设计研究院集团股份有限公司,广州,510000
  • 折叠

摘要

Abstract

Taking the evaporative total heat recovery fresh air unit as the research object,and its energy efficiency calculation model and calculation method for energy efficiency ratio are proposed.Taking a super high-rise office building in Guangzhou which uses this type of fresh air unit as an example,the energy efficiency ratio of typical air volumes are calculated.The results show that,when the total heat recovery efficiency is 60%in summer and the supply air is processed to the same enthalpy value as the indoor air,,the energy efficiency ratio of the fresh air handling unit is around 4.3.The calculation results can provide a reference for engineering designers to reasonably select this type of fresh air unit in the early design stage.

关键词

蒸发式全热回收新风机组/排风热回收/能效比/能效计算

Key words

Evaporative Total Heat Recovery Fresh Air Unit/Heat Recovery from Exhaust Air/Energy Efficiency Ratio/Energy Efficiency Calculation