| 注册
首页|期刊导航|现代医药卫生|扫描式葡萄糖监测系统对成人糖尿病患者血糖控制及知信行水平的影响

扫描式葡萄糖监测系统对成人糖尿病患者血糖控制及知信行水平的影响

顾雯 陈正方 张怡倩 黄婷玮

现代医药卫生2026,Vol.42Issue(5):1036-1039,1043,5.
现代医药卫生2026,Vol.42Issue(5):1036-1039,1043,5.DOI:10.3969/j.issn.1009-5519.2026.05.017

扫描式葡萄糖监测系统对成人糖尿病患者血糖控制及知信行水平的影响

Effect of flash glucose monitoring system on glycemic control and knowledge-attitude-practice levels in adult diabetic patients

顾雯 1陈正方 1张怡倩 1黄婷玮1

作者信息

  • 1. 常熟市第一人民医院内分泌科,江苏 常熟 215500
  • 折叠

摘要

Abstract

Objective To investigate the effect of flash glucose monitoring(FGM)system on glycemic control and knowledge-attitude-practice(KAP)levels in adult diabetic patients.Methods A total of 230 dia-betic patients admitted to our hospital from January 2022 to January 2024 were selected and randomly divided into observation group and control group,with 115 cases in each group.The control group was treated with fingertip blood glucose detection and insulin pump,while the observation group was treated with FGM com-bined with insulin pump.The blood glucose biochemical indexes[fasting blood glucose(FPG),2-hour post-prandial blood glucose(2hPG),glycosylated hemoglobin(HbA1c)],blood glucose fluctuation indexes[average blood glucose fluctuation range(MAGE),blood glucose standard deviation(SDBG),blood glucose daily aver-age difference(MODD)],as well as blood glucose reaching the standard time,insulin dosage,hypoglycemia per capita times,blood glucose reaching the standard rate,and KAP score were compared between the two groups.Results There was no significant difference in the levels of HbA1c,FPG and 2 hours FPG between the two groups before intervention(P>0.05).After the intervention,the levels of HbA1c,FPG and 2hPG in the two groups were lower than those before the intervention,and the indexes in the observation group were lower than those in the control group,with statistical significance(P<0.05).After the intervention,the time to reach the standard of blood sugar in the observation group was shorter than that in the control group,and the insulin dosage and hypoglycemia per capita times were lower than those in the control group,with statistical significance(P<0.05).Before the intervention,the levels of MAGE,SDBG and MODD between the two groups were not statistically significant(P>0.05).After the intervention,the levels of MAGE,SDBG and MODD in the two groups were lower than those before the intervention,and the indexes in the observation group were lower than those in the control group,with statistical significance(P<0.05).Before the interven-tion,there was no significant difference between the two groups in the blood glucose compliance rate and KAP scores(P>0.05).After the intervention,the blood glucose compliance rate and KAP scores in the two groups were higher than those before the intervention,and the indexes in the observation group were higher than those in the control group,with statistical significance(P<0.05).Conclusion The FGM system can effective-ly improve glycemic biochemical indicators,shorten the time to reach glycemic target,reduce insulin dosage and the risk of hypoglycemia,and enhance the KAP level in adult diabetic patients.

关键词

扫描式葡萄糖监测系统/成人糖尿病/知-信-行/血糖达标率

Key words

Flash glucose monitoring system/Adult diabetes mellitus/Knowledge-attitude-prac-tice/Glycemic target achievement rate

分类

医药卫生

引用本文复制引用

顾雯,陈正方,张怡倩,黄婷玮..扫描式葡萄糖监测系统对成人糖尿病患者血糖控制及知信行水平的影响[J].现代医药卫生,2026,42(5):1036-1039,1043,5.

基金项目

江苏省常熟市科技计划项目(csws201914). (csws201914)

现代医药卫生

1009-5519

访问量0
|
下载量0