| 注册
首页|期刊导航|中国临床药学杂志|拉考沙胺血药浓度的测定及其与抗癫痫治疗效果相关性研究

拉考沙胺血药浓度的测定及其与抗癫痫治疗效果相关性研究

高名 李哲 郭美华 刘亮 林立旺 海鑫

中国临床药学杂志2026,Vol.35Issue(4):335-340,6.
✕
中国临床药学杂志2026,Vol.35Issue(4):335-340,6.DOI:10.19577/j.1007-4406.2026.04.008

拉考沙胺血药浓度的测定及其与抗癫痫治疗效果相关性研究

Determination of lacosamide plasma concentration and its correlation with antiepileptic efficacy

高名 1李哲 2郭美华 1刘亮 1林立旺 1海鑫1

作者信息

  • 1. 哈尔滨医科大学附属第一医院药学部,哈尔滨 150001
  • 2. 哈药集团生物工程有限公司医学市场部,哈尔滨 150000
  • 折叠

摘要

Abstract

AIM To develop a liquid chromatography-tandem mass spectrometry(LC-MS/MS)method for determining lacosamide(LCM)plasma concentrations,and to analyze the correlation between LCM plasma concentrations and the antiepileptic therapy efficacy,thereby providing a reference for clinical dosage adjustment.METHODS Plasma samples were pretreated by protein precipitation with acetonitrile,using dexmedetomidine as the internal standard.Separation was achieved on a C18 column using a mobile phase of 0.2%formic acid in water and acetonitrile with gradient elution at a flow rate of 0.5 mL·min-1.The column temperature was set at 40℃,and the injection volume was 2 μL.The validated method was used to determine the steady-state trough concentrations of LCM in 128 epilepsy patients receiving regular LCM therapy.Patient demographics,clinical efficacy,and the occurrence of adverse drug reactions were collected for correlation analysis.RESULTS The method demonstrated good linearity within the concentration range of 0.50-50.00 μg·mL-1,with high accuracy and stability.The LCM plasma concentration in the 128 patients was(8.66±5.11)μg·mL-1.Three patients(2.34%)had concentrations below 1 μg·mL-1,31 patients(24.22%)had concentrations above 10 μg·mL-1,and 94 patients(73.44%)had concentrations within the recommended therapeutic range of 1-10 μg·mL-1.At the same dosage,the plasma concentration showed a moderate negative correlation with total body weight and a weak negative correlation with body mass index.No significant difference in plasma concentration was observed between the treatment-effective group and the treatment-ineffective group.However,the plasma concentration in the group experiencing adverse reactions was significantly higher than that in the group without adverse reactions[(11.90±6.03)μg·mL-1 vs(7.99±4.68)μg·mL-1,P<0.01].CONCLUSION This study successfully established a rapid,accurate,and reliable LC-MS/MS method suitable for the TDM of LCM.Clinical application analysis indicated that under standardized dosing,most patients achieved plasma concentrations within the therapeutic range.In comparison to body mass index,the plasma concentration of lacosamide demonstrates a stronger correlation with body weight.

关键词

癫痫/拉考沙胺/血药浓度/治疗药物监测

Key words

epilepsy/lacosamide/plasma drug concentration/therapeutic drug monitoring

分类

医药卫生

引用本文复制引用

高名,李哲,郭美华,刘亮,林立旺,海鑫..拉考沙胺血药浓度的测定及其与抗癫痫治疗效果相关性研究[J].中国临床药学杂志,2026,35(4):335-340,6.

基金项目

黑龙江省卫生健康委科研课题(编号20221313051086) (编号20221313051086)

中国临床药学杂志

1007-4406

访问量0
|
下载量0
段落导航相关论文