| 注册
首页|期刊导航|中国医学装备|超声监测视神经鞘减压术后视神经鞘直径变化与视野恢复的相关性研究

超声监测视神经鞘减压术后视神经鞘直径变化与视野恢复的相关性研究

李菲 李臻 赵楠 李雨

中国医学装备2026,Vol.23Issue(5):61-64,4.
中国医学装备2026,Vol.23Issue(5):61-64,4.DOI:10.3969/j.issn.1672-8270.2026.05.011

超声监测视神经鞘减压术后视神经鞘直径变化与视野恢复的相关性研究

Correlation between the ultrasound-monitored ONSD changes and the recovery of visual field after ONSF

李菲 1李臻 1赵楠 1李雨1

作者信息

  • 1. 首都医科大学宣武医院眼科 北京 100053
  • 折叠

摘要

Abstract

Objective:To investigate the association with temporal sequence between the changes of optic nerve sheath diameter(ONSD)and the recovery of visual field after optic nerve sheath fenestration(ONSF),so as to provide a quantifiable biomarker for clinical practice.Methods:Eighty-six patients who underwent ONSF at Xuanwu Hospital between 2022 and 2024 were selected.The ONSD of sagittal position at 3mm behind eyeball was measured by ultrasound,and papilledema was assessed according to the internationally standardized Frisén scale for papilledema grading(Frisén).The variation of mean damage(MD)value(ΔMD)of visual field was compared.The time points of measures included before surgery(T0),at the 1st week after surgery(T1),at the 1st month after surgery(T2)and at the 3rd month after surgery(T3).The difference of baseline was analyzed,and the time effects were assessed by using repeated measures one-way analysis of variance(ANOVA).Pearson correlation coefficients(r)were used to analyze the correlation of various indicators.Results:The postoperative ONSD of patients continuously decreased,and the difference of that between before and after surgery was significant(F=265.730,P<0.001).With the change of time,Frisnuous grading improved,and the improvement rate reached to 70.09%.The correlation analysis indicated that there were significant correlations among different variables at before surgery,at the 1st week,1st month and 3rd month after surgery,there was significant change between before and after surgery.There were significantly positive correlations between ONSD and Frisérisnts grading at different time points included before surgery,at the 1st week,1st month and 3rd month after surgery(r=0.843,0.782,0.711,0.623,P<0.05).ONSD appeared significantly negative correlation with ΔMD values before surgery(r=-0.763,P<0.05),but it appeared significantly positive correlation with that at the 1st week,1st month and 3rd month after surgery(r=0.695,0.772,0.824,P<0.05).In addition,the Frisérisnts grading appeared significantly negative correlation with ΔMD values before surgery(r=-0.684,P<0.05),but it appeared significantly positive correlation with that at the 1st week,1st month and 3rd month after surgery(r=0.732,0.753,0.795,P<0.05).Conclusion:Standardized ultrasonographic monitoring can dynamically quantify the reduction of ONSD after ONSF,which appears significantly positive association with temporal sequence to visual field.It can provide reliable non-invasive biomarker for evaluation of therapeutic efficacy.The individualized follow-up strategy can be formulated according to this research in clinical practice.

关键词

视神经鞘减压术/超声监测/视神经鞘直径/视野恢复/Frisén分级/视野平均缺损值变化量

Key words

Optic nerve sheath fenestration(ONSF)/Ultrasound monitoring/Optic nerve sheath diameter(ONSD)/Recovery of visual field/Frisén grading/Variation of mean damage(MD)

分类

医药卫生

引用本文复制引用

李菲,李臻,赵楠,李雨..超声监测视神经鞘减压术后视神经鞘直径变化与视野恢复的相关性研究[J].中国医学装备,2026,23(5):61-64,4.

基金项目

北京市科学技术项目(PX2025029) Beijing Science and technology project(PX2025029) (PX2025029)

中国医学装备

1672-8270

访问量0
|
下载量0
段落导航相关论文