| 注册
首页|期刊导航|电测与仪表|新型电力系统极端环境复合绝缘子改进闪络电压计算模型

新型电力系统极端环境复合绝缘子改进闪络电压计算模型

刘星廷 王楠 马静 王欣伟 乔新涵 朱子尚

电测与仪表2026,Vol.63Issue(6):23-30,8.
电测与仪表2026,Vol.63Issue(6):23-30,8.DOI:10.19753/j.issn1001-1390.2026.06.003

新型电力系统极端环境复合绝缘子改进闪络电压计算模型

Calculation model for improving the flash over voltage of composite insulator in extreme environment of the novel power system

刘星廷 1王楠 1马静 1王欣伟 1乔新涵 2朱子尚2

作者信息

  • 1. 国网山西省电力公司电力科学研究院,太原 030001
  • 2. 中国矿业大学 电气工程学院,江苏 徐州 221116
  • 折叠

摘要

Abstract

In order to achieve the optimized energy allocation,long-distance and high-capacity transmission is be-coming more common in the novelpower system.This requires insulators to operate in a wider geographical area,crossing different climates and geographical environments,thereby increasing the opportunities to come into contact with various sources of pollution.At present,the flashover problem of composite insulators in heavily polluted envi-ronments in special areas under the novel power systemhas not been solved.However,the existing pollution flash-over models mainly target conventional pollution levels,and there is no flashover model for insulators under heavy pollution conditions.Accurate flashover models are the key to insulation configuration and pollution flashover warn-ings under heavy pollution conditions.To this end,this paperwill study and propose a flashover model for composite insulators in extreme environments of the novel power system.Firstly,this paper puts forward an approach to work out the flashover voltage of composite insulators in the context of heavy pollution,introducing the concept of random arc,which is more in line with the arc development state under heavy pollution conditions;Deriving the residual fouling layer based on the electric axis method in electromagnetic field theory is more suitable for multi-arc states;And the key model parameters under heavy pollution conditionsare tested and corrected.The final experimental ver-ification shows that taking the pollution level of 0.4mg/cm2 as an example,AC pollution flashover voltage gradient test value of the composite insulators is 31.6 kV/m,and the model calculation value is 30.0 kV/m.The calcula-tion error and error percentage are only 1.6 kV/m and 5.06%,respectively.The maximum error percentage in calculating the AC pollution flashover voltage gradient within the 0.4 mg/cm2~1.2 mg/cm2 range is less than 10%.The calculation method proposed in this paper is highly accurate.The research results of the paper supple-ment the pollution flashover model under conventional pollution levels,which has important reference significance for insulation configuration and pollution flashover warning under high pollution conditions.

关键词

新型电力系统/极端环境/绝缘子/随机电弧/污闪

Key words

novel power system/extreme environment/insulator/random arc/pollution flashover

分类

信息技术与安全科学

引用本文复制引用

刘星廷,王楠,马静,王欣伟,乔新涵,朱子尚..新型电力系统极端环境复合绝缘子改进闪络电压计算模型[J].电测与仪表,2026,63(6):23-30,8.

基金项目

国网山西省电力公司科技项目(52053023000H) (52053023000H)

电测与仪表

1001-1390

访问量0
|
下载量0
段落导航相关论文