地震地磁观测与研究2026,Vol.47Issue(1):54-64,11.DOI:10.3969/j.issn.1003-3246.2026.01.008
怀来形变观测山洞密封保温改造对摆式倾斜仪观测的影响
Influence of sealing and thermal insulation renovation of Huailai deformation observation cave on pendulum tiltmeter observations
摘要
Abstract
Since the sealing and thermal insulation renovation of the Huailai deformation observation cave was completed in 2018,the quality of observation data from the vertical pendulum and horizontal pendulum tiltmeters installed in the cave has steadily improved,earning numerous awards in national evaluations of similar observation datasets.This paper briefly describes the renovation measures implemented for the cave,comparatively analyzes the effects of environmental factors such as cave humidity and meteorological conditions on observation quality before and after the renovation,and evaluates the quality and accuracy of the observation data.The results demonstrate that the overall thermal insulation renovation has achieved remarkable moisture-proofing,optimized the observation environment,and reduced disturbances from meteorological factors such as strong winds and air pressure,thus effectively improving the observation accuracy of pendulum-type instruments.The renovation project for the deformation observation cave at Huailai Seismic Station has been proven successful,and its experience can serve as a valuable reference for other seismic stations.关键词
倾斜观测/洞室改造/数据质量/干扰因素Key words
tilt observation/cave renovation/data quality/interference factors引用本文复制引用
池海江,张广莉,只楠..怀来形变观测山洞密封保温改造对摆式倾斜仪观测的影响[J].地震地磁观测与研究,2026,47(1):54-64,11.基金项目
河北省地震局科技星火计划(项目编号:DZ2025081900017) (项目编号:DZ2025081900017)