| 注册
首页|期刊导航|东北电力技术|配电网SVG区域故障成因分析及研究

配电网SVG区域故障成因分析及研究

吴晗序 刘钧迪 金元元 刘晓丽 王金辉

东北电力技术2026,Vol.47Issue(6):28-32,45,6.
✕
东北电力技术2026,Vol.47Issue(6):28-32,45,6.

配电网SVG区域故障成因分析及研究

Analysis and Research on Causes of Regional Faults in Distribution Network SVG

吴晗序 1刘钧迪 1金元元 2刘晓丽 2王金辉2

作者信息

  • 1. 国网辽宁省电力有限公司电力科学研究院,辽宁 沈阳 110006
  • 2. 辽宁东科电力有限公司,辽宁 沈阳 110179
  • 折叠

摘要

Abstract

According to the problem of frequent regional faults of static var generator(SVG)devices in distribution networks,through statistical analysis of the operation data of 10 kV SVG in Liaoning area,combined with large-capacity true-type tests,it reproduces typical fault processes such as power module breakdown,communication link interruption and cooling system failure.It analyzes the causes of faults from multiple dimensions such as equipment design,heat dissipation system,communication reliability and operation and maintenance management.It proposes systematic improvement measures such as optimizing the three-proof process of power modu-les,redundant design of optical fiber communication,improvement of air cooling/water cooling systems,and standardization of opera-tion and maintenance procedures.It verifies the fault mechanism under the coupling effect of multiple factors through true-type testing and forms a targeted comprehensive solution.The results show that the proposed method can reduce the equipment failure rate,provi-ding support and practical basis for improving the reliable operation of SVG in the distribution network.

关键词

无功补偿/SVG/故障分析/真型试验

Key words

reactive power compensation/SVG/fault analysis/true-type testing

分类

信息技术与安全科学

引用本文复制引用

吴晗序,刘钧迪,金元元,刘晓丽,王金辉..配电网SVG区域故障成因分析及研究[J].东北电力技术,2026,47(6):28-32,45,6.

东北电力技术

1004-7913

访问量0
|
下载量0
段落导航相关论文