考虑需求侧响应的商业用户风光储自备电源配置方法

游沛羽 王智冬 杨卫红 杨晓东 武诚 彭丽

电力建设2026,Vol.47Issue(6):68-81,14.
✕
电力建设2026,Vol.47Issue(6):68-81,14.DOI:10.12204/j.issn.1000-7229.2026.06.006

考虑需求侧响应的商业用户风光储自备电源配置方法

Planning Strategy for Commercial User-Sited Wind,Photovoltaic,and Storage Power Sources Based on Demand-Side Response

游沛羽 1王智冬 1杨卫红 1杨晓东 2武诚 3彭丽4

作者信息

  • 1. 国网经济技术研究院有限公司,北京市 102209
  • 2. 国网福建省电力有限公司,福州市 350003
  • 3. 国网山东省电力公司,济南市 250001
  • 4. 华电电力科学研究院有限公司,北京市 100039
  • 折叠

摘要

Abstract

[Objective]To reduce the total energy costs for commercial entities,satisfy renewable energy consumption mandates,improve the utilization rate of new energy,and alleviate reverse overload of distribution transformers,this study develops a configuration strategy for user-sited power sources including wind,solar and energy storage.The strategy accounts for time-of-use pricing curve,load guideline and load baseline demand response(DR).Furthermore,the constraints allowing reverse power transmission are incorporated,and the effectiveness of participating in three types of DR to minimize total energy costs is evaluated and compared.[Methods]A two-layer optimization model was established with the objective of minimizing total energy costs.This model involves alternating iterations between the configuration of user-sited power sources during the planning phase and the determination of the load baseline during the operational phase.The upper-level model considers the maximum values of multiple predicted new energy curves at any given time to establish a user-sited power source configuration model,and solves the capacity of new energy,energy storage,and nominal discharge time.The lower-level model calculates the mathematical expectation of total energy costs based on the outputs of the upper-level model and the probability of multiple predicted new energy curves.The mathematical expectation of transmission curves is used as the load baseline and fed back to the upper-level model.This iterative process continues until the results of two consecutive user-sited power source configuration and the load baseline are identical.By setting a reverse transmission constraint(not exceeding 20%of photovoltaic generation)and adjusting time-of-use pricing,benchmark incentive prices,and load guidelines,the influence on economic indicators was analyzed.A large commercial complex in a coastal province of China served as a case study for calculation and evaluation to verify the strategy's effectiveness from the perspective of reducing total energy costs.[Results]From the perspective of mathematical expectation,the proposed model reduced total energy costs by 2%to 10%compared to control schemes without user-sited power sources.The similarity when participating in baseline DR ranged from 98%to 100%,significantly higher than the 82%to 86%observed with guideline DR.Compared to guideline DR,participating in baseline DR reduced total energy costs by an additional 6%to 10%.Furthermore,the proportions of photovoltaic reverse transmission remained within 0%to 10%.[Conclusions]The strategy proposed in this paper satisfies the renewable energy consumption weights mandated provincial power grids while achieving high similarity between the load baseline and the transmission curve.The inclusion of reverse transmission constraints allows for an increased scale of user-sited power sources,significantly reducing the total energy costs for commercial users.

关键词

风光储自备电源/用能总成本/需求侧响应(DR)/反向输电/负荷准线/负荷基线

Key words

user-sited wind,photovoltaic and storage power sources/total energy cost/demand response(DR)/reverse transmission/load guideline/load baseline

分类

信息技术与安全科学

引用本文复制引用

游沛羽,王智冬,杨卫红,杨晓东,武诚,彭丽..考虑需求侧响应的商业用户风光储自备电源配置方法[J].电力建设,2026,47(6):68-81,14.

基金项目

智能电网国家科技重大专项(2025ZD0805001) This work is supported by Smart Grid National Science and Technology Major Project of China(No.2025ZD0805001). (2025ZD0805001)

电力建设

1000-7229

访问量0
|
下载量0
段落导航相关论文