节能2026,Vol.45Issue(5):126-129,4.DOI:10.3969/j.issn.1004-7948.2026.05.028
基于"三改联动"的电锅炉负荷响应与效率提升分析
Analysis of load response and efficiency improvement of electric boilers based on the'three reforms linkage'
隋克诗 1李亚海 1金杭周1
作者信息
- 1. 华电新疆乌苏能源有限公司,新疆 乌苏 833099
- 折叠
摘要
Abstract
In response to the demand for the'three reforms linkage'transformation of coal-fired power units,taking the electric boiler system as the research object,a modular capacity configuration and multi-level heat storage integration scheme are proposed,and a multi-agent collaborative control strategy is constructed.Deep peak shaving performance testing,fast response characteristic verification,and multi scenario operation tests are carried out through a 350 MW unit engineering example.The results show that the minimum load of the unit can be reduced to 55 MW,and the load regulation rate can reach 30 MW/min.The thermal cycle efficiency increased by 3.50%,and the coal consumption for power supply decreased by 6.28 g/kWh.关键词
三改联动/电锅炉/负荷响应/深度调峰/效率提升Key words
three reforms linkage/electric boiler/load response/deep peak shaving/efficiency improvement分类
能源科技引用本文复制引用
隋克诗,李亚海,金杭周..基于"三改联动"的电锅炉负荷响应与效率提升分析[J].节能,2026,45(5):126-129,4.