| 注册
首页|期刊导航|热力发电|660 MW超超临界四角切圆锅炉烟气再循环墙式布置方式优化数值模拟

660 MW超超临界四角切圆锅炉烟气再循环墙式布置方式优化数值模拟

梁杰 何闯 任利明 李源 王锋涛 董行 宋贺 马仑 方庆艳

热力发电2026,Vol.55Issue(6):164-174,11.
热力发电2026,Vol.55Issue(6):164-174,11.DOI:10.19666/j.rlfd.202509052

660 MW超超临界四角切圆锅炉烟气再循环墙式布置方式优化数值模拟

Numerical simulation of wall-mounted FGR arrangement optimization for a 660 MW ultra-supercritical tangentially-fired boiler

梁杰 1何闯 2任利明 1李源 1王锋涛 3董行 4宋贺 4马仑 5方庆艳2

作者信息

  • 1. 润电能源科学技术有限公司,河南 郑州 450052
  • 2. 华中科技大学煤燃烧与低碳利用全国重点实验室,湖北 武汉 430074
  • 3. 西安交通大学能源与动力工程学院,陕西 西安 710049
  • 4. 华润电力(锦州)有限公司,辽宁 锦州 121000
  • 5. 武汉理工大学安全科学与应急管理学院,湖北 武汉 430070
  • 折叠

摘要

Abstract

[Objective]To address the issues of low reheated steam temperature and local overheating of platen superheaters(PSH)during low-load operation of a 660 MW ultra-supercritical tangentially fired once-reheat boiler,this study proposed a wall-mounted flue gas recirculation(FGR)arrangement in the burner region.The aim was to synergistically raise reheated steam temperature and suppress PSH overheating while maintaining combustion stability.[Methods]Numerical simulation was performed at 40%rated load to optimize the proposed layout.First,the baseline case and corner-mounted and wall-mounted concentrated FGR arrangements were compared.Subsequently,the feasibility of wall-mounted grouped injection was investigated.[Results]The results indicated that:corner-mounted FGR significantly increased the ignition distance of pulverized coal jets,which adversely affected low-load combustion stability.Both fire-side and rear-side concentrated FGR increased the heat absorption of the high-temperature reheater,but neither could simultaneously mitigate PSH local overheating.Fire-side grouped FGR substantially enhanced heat absorption of the reheater but still carried a risk of PSH overheating,whereas rear-side grouped FGR reduced the overheating risk but yielded only limited reheater improvement.A combined grouped arrangement,in which flue gas was injected through the two lower layers on the fire-side wall together with the upper layer on the rear-side wall,increased the heat absorption of the reheater by 18.9%,effectively mitigated local overheating of the PSH,and maintained stable combustion.[Conclusion]These findings provide design and optimization references for safe,flexible,and efficient boiler operation across wide load ranges in next-generation coal-fired power plants.

关键词

四角切圆锅炉/烟气再循环/再热汽温/数值模拟/优化

Key words

tangentially fired boiler/flue gas recirculation/reheated steam temperature/numerical simulation/optimization

引用本文复制引用

梁杰,何闯,任利明,李源,王锋涛,董行,宋贺,马仑,方庆艳..660 MW超超临界四角切圆锅炉烟气再循环墙式布置方式优化数值模拟[J].热力发电,2026,55(6):164-174,11.

基金项目

国家重点研发计划项目(2024YFB4106103) National Key Research and Development Program of China(2024YFB4106103) (2024YFB4106103)

热力发电

1002-3364

访问量0
|
下载量0
段落导航相关论文