| 注册
首页|期刊导航|电力建设|基于节点碳势的互联数据中心电-碳协同调度策略

基于节点碳势的互联数据中心电-碳协同调度策略

郇嘉嘉 刘嘉文 刘国中 文福拴 陈碧云 郭少卿

电力建设2026,Vol.47Issue(7):90-100,11.
电力建设2026,Vol.47Issue(7):90-100,11.DOI:10.12204/j.issn.1000-7229.2026.07.007

基于节点碳势的互联数据中心电-碳协同调度策略

Electricity-Carbon Coordinated Dispatching Strategy for Interconnected Data Centers Based on Nodal Carbon Potential

郇嘉嘉 1刘嘉文 1刘国中 2文福拴 3陈碧云 4郭少卿2

作者信息

  • 1. 广东电网有限责任公司电网规划研究中心,广州市 510335
  • 2. 东莞理工学院电信工程与智能化学院,广东省 东莞市 523808
  • 3. 浙江大学电气工程学院,杭州市 310027
  • 4. 广西大学电气工程学院,南宁市 530004
  • 折叠

摘要

Abstract

[Objective]Under the wave of digital transformation in various sectors,the data center industry is booming and showing a new trend of clustering and wide-area interconnection.Given the high energy consumption and high carbon emissions that are common in data centers,this paper aims to guide them to actively participate in the low-carbon dispatching of the power grid based on the spatio-temporal flexibility of their computing loads,in order to achieve the goals of energy conservation,carbon reduction,and economic operation for both data centers and the power grid.[Methods]This paper proposes a high-precision dynamic carbon emission accounting method,which takes into account the spatio-temporal differences in network losses and carbon emissions.It accurately calculates the key"nodal carbon potential"signal through a power iteration traceability algorithm and,based on this signal,proposes a coordinated two-layer dispatching model for interconnected data centers and the power grid,where the upper-layer model aims to minimize the operation cost,carbon emissions,and renewable energy curtailment,while the lower-layer model aims to minimize the integrated electricity-carbon cost.The dispatching model interacts and iterates through the carbon potential and load adjustment signals between the upper and lower layers to find the optimal dispatching strategy for the system.[Results]The case study based on the improved IEEE 39-bus system shows that under the proposed coordinated dispatching strategy,data centers actively transfer online loads to low-carbon potential nodes for processing during high-carbon potential periods and delay the processing of local offline loads.During low-carbon potential periods,they take on more online loads and concentrate on processing previously delayed offline loads,achieving significant energy conservation and carbon reduction effects.[Conclusions]The two-layer optimization model proposed in this paper can effectively guide data centers to achieve economic and low-carbon coordination,providing a new technical tool for the green transition of data centers and the low-carbon dispatching of the power grid.

关键词

数据中心/碳排放流/电碳协同/优化调度

Key words

data center/carbon emission flow/electricity-carbon synergy/optimal dispatching

分类

信息技术与安全科学

引用本文复制引用

郇嘉嘉,刘嘉文,刘国中,文福拴,陈碧云,郭少卿..基于节点碳势的互联数据中心电-碳协同调度策略[J].电力建设,2026,47(7):90-100,11.

基金项目

国家自然科学基金项目(52267006) (52267006)

广东省基础与应用基础联合基金(2023A1515140009) This work is supported by National Natural Science Foundation of China(No.52267006)and Guangdong Basic and Applied Basic Research Foundation(No.2023A1515140009). (2023A1515140009)

电力建设

1000-7229

访问量0
|
下载量0
段落导航相关论文