| 注册
首页|期刊导航|广东电力|下击暴流作用下输电塔线风致响应及易损性研究

下击暴流作用下输电塔线风致响应及易损性研究

罗华峰 范文琪 唐亚男 周嘉程 段忠东 王振国

广东电力2026,Vol.39Issue(8):105-116,12.
✕
广东电力2026,Vol.39Issue(8):105-116,12.DOI:10.3969/j.issn.1007-290X.2026.08.010

下击暴流作用下输电塔线风致响应及易损性研究

Wind-induced Response and Fragility Analysis of Transmission Tower-line Systems Under Downburst Winds

罗华峰 1范文琪 2唐亚男 3周嘉程 4段忠东 4王振国1

作者信息

  • 1. 国网浙江省电力有限公司电力科学研究院,浙江 杭州 310014
  • 2. 国网电力工程研究院有限公司,北京 100069
  • 3. 哈尔滨工业大学(深圳),广东 深圳 518055||中共合肥市委党校(合肥行政学院),安徽 合肥 230031
  • 4. 哈尔滨工业大学(深圳),广东 深圳 518055
  • 折叠

摘要

Abstract

Downburst winds are characterized by high wind speed,short duration and strong spatial localization,whereas current wind-resistant design of transmission lines still insufficiently considers the wind load characteristics and tower-line coupling effects.To investigate the dynamic response and fragility characteristics of transmission tower-line systems under downburst winds,this study employs computational fluid dynamics simulation,finite element dynamic analysis and Monte Carlo simulation to establish a three-dimensional downburst wind field and a 220 kV transmission tower-line system model.By comparing the wind speed profile simulations obtained using the Reynolds stress model(RSM)and shear stress transport(SST)k-ω turbulence model,the study analyzes the response differences between the equivalent tower-line model and the three-tower four-line coupled model at different wind directions.Fragility curves are then developed by taking initial member yielding and global yielding as damage states.The results show that the RSM turbulence model can reasonably reproduce the vertical distribution of near-ground horizontal wind speed.When the wind direction is perpendicular to the conductors,the conductors and insulator strings transmit additional lateral forces and torsional effects to the tower through the cross-arms,leading to an approximately 27%increase in tower-top displacement in the three-tower four-line coupled model compared with the equivalent tower-line model.Although downburst winds can produce high local wind speed,their limited spatial extent results in relatively lower wind-induced risk for towers located outside the core wind speed region.The findings provide a reference for wind-resistant checking and fragility assessment of transmission tower-line systems in regions prone to severe convective winds.

关键词

下击暴流/输电塔线/动力响应/失效模式/易损性

Key words

downburst/transmission tower line/dynamic response/failure mode/fragility

分类

信息技术与安全科学

引用本文复制引用

罗华峰,范文琪,唐亚男,周嘉程,段忠东,王振国..下击暴流作用下输电塔线风致响应及易损性研究[J].广东电力,2026,39(8):105-116,12.

基金项目

国家自然科学基金联合基金项目(U2142206) (U2142206)

国网浙江省电力有限公司科技项目(B311DS24001A) (B311DS24001A)

广东电力

1007-290X

访问量0
|
下载量0
段落导航相关论文