家电科技2026,Vol.3Issue(3):54-59,6.DOI:10.19784/j.cnki.issn1672-0172.2026.03.008
基于全链条风险评估的R290家用空调安全等级量化研究
Quantitative study on the safety level of R290 household air conditioners based on full-chain risk assessment
摘要
Abstract
R290,as an A3 classified flammable refrigerant,faces risks of leakage and combustion during its promotion in household air conditioners.To systematically evaluate the full-chain risk levels of different products,a risk assessment quantification method was adopted to quantitatively grade five types of products:split-type,portable,window-type,saddle-type,and indirect cooling unit.The results indicate that indirect cooling units(2.00)and saddle-type units(2.65)are classified as low-risk;window-type air conditioners(5.61)and portable air conditioners(6.36)are classified as medium-risk;split-type air conditioners(7.56)are classified as high-risk.Sensitivity analysis of refrigerant charge shows that split-type air conditioners are the most sensitive to changes in refrigerant charge,with an increase of 57%;portable and window-type air conditioners follow,with increases of 38%and 45%,respectively;saddle-type units and indirect cooling units,due to their refrigerant circuits being entirely placed outdoors,show no variation in indoor combustion risk with changes in refrigerant charge.This provides a reference for the full-chain risk prevention and control and safe promotion of R290 household air conditioners.关键词
泄漏燃爆/家用空调/风险指数/风险分级Key words
R290/Leakage and explosion/Household air conditioners/Risk index/Risk grading分类
信息技术与安全科学引用本文复制引用
柴浩雁,马国远,聂俊瑞..基于全链条风险评估的R290家用空调安全等级量化研究[J].家电科技,2026,3(3):54-59,6.基金项目
国家自然科学基金项目(52478075). (52478075)