云南水力发电2026,Vol.42Issue(7):21-23,3.DOI:10.3969/j.issn.1006-3951.2026.07.005
H-ADCP在感潮河段流量测验的应用
Application of H-ADCP in Flow Measurement of Tidal River Section
姚志坚 1许玉联 1张智全1
作者信息
- 1. 广东省水文局广州水文分局,广东 广州 510150
- 折叠
摘要
Abstract
Based on 78 flow data measured at Sanshanjiao Hydrological Station,the H-ADCP fitted in this paper represents the relationship between flow velocity and average flow velocity at the cross-section.Through three types of tests,including symbol test,fitting line test,and deviation value test,both random error and systematic error meet the requirements of Class I accuracy station specified in T/CHES 61-2021"Acoustic Doppler Flow Measurement Specification",proving that H-ADCP is feasible and reliable for tidal flow monitoring at Sanshanjiao Hydrological Station.This indicates that H-ADCP is feasible for monitoring flow in tidal rivers.关键词
三善滘/H-ADCP/比测/率定Key words
Sanshanjiao/H-ADCP/comparison test/calibration分类
建筑与水利引用本文复制引用
姚志坚,许玉联,张智全..H-ADCP在感潮河段流量测验的应用[J].云南水力发电,2026,42(7):21-23,3.