| 注册
首页|期刊导航|中国临床药学杂志|基于冠状动脉CT血管成像图像质量的碘克沙醇注射液仿制药与原研药临床等效性评价

基于冠状动脉CT血管成像图像质量的碘克沙醇注射液仿制药与原研药临床等效性评价

姜慧妍 吴晓艳 邵明冉 严思敏

中国临床药学杂志2026,Vol.35Issue(6):513-517,5.
✕
中国临床药学杂志2026,Vol.35Issue(6):513-517,5.DOI:10.19577/j.1007-4406.2026.06.006

基于冠状动脉CT血管成像图像质量的碘克沙醇注射液仿制药与原研药临床等效性评价

Clinical equivalence of generic and original iodixanol injection assessed by coronary CT angiography image quality

姜慧妍 1吴晓艳 2邵明冉 2严思敏1

作者信息

  • 1. 南京大学医学院附属鼓楼医院药学部,南京 210008
  • 2. 南京大学医学院附属鼓楼医院医学影像科,南京 210008
  • 折叠

摘要

Abstract

AIM To compare the image quality between generic and original iodixanol injections in coronary computed-tomography angiography(CCTA),providing imaging evidence for validating the clinical equivalence of the generic product.METHODS Patients who underwent CCTA using iodixanol injection between January 1,2022,and October 31,2022,were enrolled and divided into a generic group(n=86)and an original group(n=92).Subjective image quality assessment was performed using the Likert scale for the left main coronary artery(LM),proximal left anterior descending artery(LAD),proximal left circumflex artery(LCX),and proximal right coronary artery(RCA).Objective metrics,including CT values,standard deviation(SD),signal-to-noise ratio(SNR),and contrast-to-noise ratio(CNR),were measured in the luminal and adjacent adipose regions of LM,LAD,LCX,and RCA.RESULTS Both groups exhibited subjective image quality scores ≥ 3 for all coronary segments(over 95%),with no significant intergroup differences(P>0.05).The CT value,SD value,SNR and CNR of the 2 groups all reached the clinical diagnostic threshold.The LM-CT values,LAD-CT values,RCA-CT values,LM-SD values,and LCX-SD values in the generic group were significantly higher than those in the original group(all P<0.05).However,there were no statistically significant differences in SNR and CNR,across all vascular territories(the 95%CIs of all differences included 0,with P>0.05,and effect sizes r ranged from 0 to 0.13).CONCLUSION The generic iodixanol injection demonstrates equivalent image quality to the original product in coronary artery imaging,supporting its role as a cost-effective alternative for diagnosing coronary pathologies.

关键词

碘克沙醇注射液/造影剂/疗效评价/图像质量

Key words

iodixanol injection/contrast agent/efficacy/image quality

分类

医药卫生

引用本文复制引用

姜慧妍,吴晓艳,邵明冉,严思敏..基于冠状动脉CT血管成像图像质量的碘克沙醇注射液仿制药与原研药临床等效性评价[J].中国临床药学杂志,2026,35(6):513-517,5.

基金项目

南京药学会会企合作药物临床综合评价科研专项资助项目(编号2023ZP01) (编号2023ZP01)

中国临床药学杂志

1007-4406

访问量0
|
下载量0
段落导航相关论文