| 注册
首页|期刊导航|光学精密工程|低压水汽及氢氧同位素波长调制检测

低压水汽及氢氧同位素波长调制检测

王立一 李想 曹乃亮 邓昊 胡海飞 糜小涛 阚瑞峰

光学精密工程2026,Vol.34Issue(15):2289-2301,13.
✕
光学精密工程2026,Vol.34Issue(15):2289-2301,13.DOI:10.37188/OPE.20263415.2289

低压水汽及氢氧同位素波长调制检测

Wavelength-modulation detection for water vapor and hydrogen-oxygen isotopes under low-pressure conditions

王立一 1李想 2曹乃亮 2邓昊 2胡海飞 3糜小涛 3阚瑞峰2

作者信息

  • 1. 中国科学院 合肥物质科学研究院,安徽 合肥 230031||中国科学技术大学,安徽 合肥 230026
  • 2. 中国科学院 合肥物质科学研究院,安徽 合肥 230031
  • 3. 中国科学院 长春光学精密机械与物理研究所,吉林 长春 130033
  • 折叠

摘要

Abstract

Weak absorption and spectral overlap limit trace isotope detection under low-pressure dynamic conditions.To address this issue,a wavelength modulation spectroscopy(WMS)method is proposed for hydrogen and oxygen isotope measurements in water vapor.A distributed feedback(DFB)laser centered at 1.863 μm was employed,and a miniaturized detection system with a 12 m optical path and an 80 cm³ ab-sorption cell was developed.By means of a single scan,simultaneous detection of H216O,H217O,H218O,and HDO was achieved.Calibration experiments were performed using different standard water samples,and relationships were established between the fitted integrated area ratios and isotope reference values.Hydrogen and oxygen isotope ratios,together with the corresponding δ values,were then obtained.The fitted integrated areas exhibited linear relationships with water vapor pressure,with correlation coefficients exceeding 0.99.Under a steady pressure of 340 Pa,the optimal integration times were determined to be 18 s,23 s,and 20 s for δD,δ18O,and δ17O,respectively.The minimum Allan deviations were 2.015‰,3.636‰,and 1.317‰.Simulated lunar-soil experiments further verified dynamic isotope monitoring,and isotope variations during adsorption fractionation were successfully captured.The 10%-90%pressure response time was 71 s.A comparison experiment was also conducted using a direct absorption system at 2.731 μm as a reference,with an optical path length of 25 m.Consistent δD variation trends were ob-served in both systems.The proposed method enables steady-state and dynamic measurements of hydro-gen and oxygen isotopes in water vapor under low-pressure conditions,thereby providing technical support for miniaturized in situ isotope detection in dynamic environments.

关键词

低压水汽/氢氧同位素/波长调制光谱法/同位素反演

Key words

low-pressure water vapor/hydrogen and oxygen isotopes/wavelength modulation spectros-copy/isotope retrieval

分类

信息技术与安全科学

引用本文复制引用

王立一,李想,曹乃亮,邓昊,胡海飞,糜小涛,阚瑞峰..低压水汽及氢氧同位素波长调制检测[J].光学精密工程,2026,34(15):2289-2301,13.

基金项目

国家重点研发计划资助项目(No.2024YFE0201000) (No.2024YFE0201000)

国家自然科学基金资助项目(No.62205346) (No.62205346)

光学精密工程

1004-924X

访问量0
|
下载量0
段落导航相关论文