| 注册
首页|期刊导航|电力系统及其自动化学报|有源配电网保护整定方法及分布式电源准入容量分析

有源配电网保护整定方法及分布式电源准入容量分析

陈晓龙 郑郅彦 李永丽 王鸿 梁伟宸 李烜

电力系统及其自动化学报2026,Vol.38Issue(8):77-90,14.
✕
电力系统及其自动化学报2026,Vol.38Issue(8):77-90,14.DOI:10.19635/j.cnki.csu-epsa.001750

有源配电网保护整定方法及分布式电源准入容量分析

Protection Setting Method for Active Distribution Networks and Analysis of Distributed Generation Penetration Capacity

陈晓龙 1郑郅彦 1李永丽 1王鸿 1梁伟宸 2李烜2

作者信息

  • 1. 智能配用电装备与系统全国重点实验室(天津大学),天津 300072
  • 2. 国网冀北电力有限公司电力科学研究院,北京 100045
  • 折叠

摘要

Abstract

To address the issues of failure to operate or maloperation of traditional three-stage overcurrent protection in distribution networks which are caused by the integration of inverter-interfaced distributed generators represented by photovoltaic sources,a protection setting method for active distribution networks is proposed in this paper,and an analy-sis of the corresponding distributed generation penetration capacity is also performed.First,considering the influences of phase-to-phase short-circuit fault types,fault locations and operation modes,the variation patterns of fault current se-quence components,fault phase current and phase-to-phase current in the fault phase under phase-to-phase short-cir-cuit faults in active distribution networks are analyzed.On this basis,an effective simplification method aggregating mul-tiple distributed generators on the same line is adopted to comprehensively incorporate the output current from distribut-ed generators and their grid-connection locations into the protection setting.In addition,combined with the traditional three-stage overcurrent protection setting methodology,a current protection setting method for active distribution net-works based on phase-to-phase current in the fault phase is put forward.Furthermore,with the combination of selectivity and sensitivity constraints on the protection,the calculation methods for the penetration capacity of distributed genera-tors which locate upstream of the protection,within the protection zone and downstream of the protection are given,re-spectively.Modeling and fault simulation of active distribution networks conducted in PSCAD/EMTDC verify the correct-ness of the fault characteristic analysis results,as well as the effectiveness of the proposed protection setting method.

关键词

逆变型分布式电源/配电网/故障特性/故障相相间电流/电流保护整定/准入容量

Key words

inverter-interfaced distributed generator/distribution network/fault characteristic/phase-to-phase current in fault phase/current protection setting/penetration capacity

分类

信息技术与安全科学

引用本文复制引用

陈晓龙,郑郅彦,李永丽,王鸿,梁伟宸,李烜..有源配电网保护整定方法及分布式电源准入容量分析[J].电力系统及其自动化学报,2026,38(8):77-90,14.

基金项目

国家重点研发计划资助项目(2022YFE0208800).国网冀北电力有限公司科技项目(B3018K24009). (2022YFE0208800)

电力系统及其自动化学报

1003-8930

访问量0
|
下载量0
段落导航相关论文