| 注册
首页|期刊导航|分析测试学报|加速溶剂萃取/气相色谱-三重四极杆质谱法测定大气中苯并三唑类紫外吸收剂

加速溶剂萃取/气相色谱-三重四极杆质谱法测定大气中苯并三唑类紫外吸收剂

刘梦 杜涛 刘金林 刘承友 唐晗昱 张利飞 张烃

分析测试学报2026,Vol.45Issue(9):1910-1917,8.
✕
分析测试学报2026,Vol.45Issue(9):1910-1917,8.DOI:10.12452/j.fxcsxb.26032701

加速溶剂萃取/气相色谱-三重四极杆质谱法测定大气中苯并三唑类紫外吸收剂

Determination of Benzotriazole Ultraviolet Absorbers in the Ambient Atmosphere by Accelerated Solvent Extraction/Gas Chromatography-Triple Quadrupole Mass Spectrometry

刘梦 1杜涛 2刘金林 3刘承友 3唐晗昱 3张利飞 3张烃3

作者信息

  • 1. 陕西省环境介质痕量污染物监测预警重点实验室,陕西 西安 710054||国家环境分析测试中心,北京 100029||生态环境部二(噁)英污染控制重点实验室,北京 100029
  • 2. 陕西省环境介质痕量污染物监测预警重点实验室,陕西 西安 710054
  • 3. 国家环境分析测试中心,北京 100029||生态环境部二(噁)英污染控制重点实验室,北京 100029
  • 折叠

摘要

Abstract

In this study,a sensitive and reliable analytical method was established for the simultane-ous determination of gaseous and particulate benzotriazole ultraviolet absorbers(BUVs)in ambient air.The target analytes included four common BUVs:UV-320,UV-326,UV-327,and UV-328.Specifically,a high-volume air sampler was used to collect gaseous and particulate BUVs sepa-rately,with quartz fiber filters(QFF)for particulate phase and polyurethane foam(PUF)/XAD-2 res-in for gaseous phase.Air samples were extracted by accelerated solvent extraction,purified by silica cartridges,and analyzed by gas chromatography-triple quadrupole mass spectrometry.Method vali-dation experiments were carried out to evaluate the performance of the established method,and the results showed that the four target compounds exhibited a good linear relationship in the concentration range of 1-200 ng/mL,with correlation coefficients(r)all greater than 0.999.The method detection limits ranged from 0.4 to 0.5 pg/m3,and the quantitation limits ranged from 1.6 to 2.0 ng/m3,which was sufficiently low to detect trace levels of BUVs in ambient air.The recoveries of the target analytes in QFF,PUF,and XAD-2 samples were 83.0%-103%,74.9%-108%,83.4%-96.0%,and the relative standard deviations(RSDs)were less than 10%for all target analytes,respectively.The method was used to monitor BUVs in ambient air samples of Beijing,and UV-326 and UV-328 were detected with concentration range of 0.9-6.8 pg/m3,while UV-320 and UV-327 were not de-tected in any samples.The established method is highly sensitive and accurate,which can fully meet the monitoring requirements for trace BUVs in the ambient atmosphere.It not only provides a reliable analytical tool for further in-depth research on the environmental behavior and ecological risks of BU-Vs in the atmospheric environment but also lays a solid foundation for the environmental monitoring and risk control of BUVs.

关键词

苯并三唑类/紫外吸收剂/大气监测/气相色谱-三重四极杆质谱/加速溶剂萃取

Key words

benzotriazole/ultraviolet absorbers/air monitoring/gas chromatography-triple quad-rupole mass spectrometry/accelerated solvent extraction

分类

化学化工

引用本文复制引用

刘梦,杜涛,刘金林,刘承友,唐晗昱,张利飞,张烃..加速溶剂萃取/气相色谱-三重四极杆质谱法测定大气中苯并三唑类紫外吸收剂[J].分析测试学报,2026,45(9):1910-1917,8.

基金项目

京津冀环境综合治理国家科技重大专项资助(2025ZD1203300) (2025ZD1203300)

陕西省环境介质痕量污染物监测预警重点实验室开放基金项目(SHJKFJJ-YB-202402) (SHJKFJJ-YB-202402)

分析测试学报

1004-4957

访问量0
|
下载量0
段落导航相关论文