化工学报2026,Vol.77Issue(8):4377-4385,9.DOI:10.11949/0438-1157.20260244
斯特林型制冷机污染失效的研究进展
Research progress on contamination failure of Stirling type refrigerators
摘要
Abstract
Stirling type refrigerators are compact,highly reliable,and operate across a broad refrigeration temperature range,making them widely used in cryogenic applications.However,their applications often require strict temperature control or are not maintenance-friendly.Currently,the most significant factor affecting their performance is performance failure caused by working fluid contamination during operation.This paper reviews the research progress on contamination-induced failure in Stirling type refrigerators in China and abroad.It summarizes the results on contaminant species and lifetime tests.The paper focuses on the relationship between performance changes and different contaminants,and on the distribution characteristics of contaminant solids.Gases with high phase transition temperatures,adsorbed on the internal surfaces of the refrigerator,gradually desorb and diffuse during operation.Then they desublimate at the coldest end of the machine,which increases flow resistance and regenerator loss and leads to periodic performance fluctuations.Finally,it points out the mechanisms and parameters that still need to be clarified,and provides guidance for the future development of long-lifespan Stirling type refrigerators.关键词
斯特林型制冷机/污染/性能失效/回热器/相变/热力学Key words
Stirling type refrigerator/pollution/performance degradation/regenerator/phase change/thermodynamics分类
通用工业技术引用本文复制引用
朱一帆,朱浩,王浩熠,陈曦..斯特林型制冷机污染失效的研究进展[J].化工学报,2026,77(8):4377-4385,9.基金项目
国家自然科学基金项目(52376012) (52376012)