A leakage accident occurred in the main circuit system valve of a nuclear power unit.The causes of the valve leakage were analyzed using macroscopic observation,radiographic testing,chemical composition analysis,mechanical property testing,metallographic examination,scanning electron microscopy and energy spectrum analysis.The results show that microcracks and microvoids were present in the mold closing area of the valve body.The Cr and Mn contents inside the cracks were abnormally high,and steps existed at the interface between the base material and weld seam on both sides of the cracks.The crack morphology did not match the characteristics of welding hot cracks,indicated it was an original crack defect formed during the casting manufacturing stage of the valve body.Under the combined action of subsequent welding residual stress and service load stress,the cracks continued to propagate,ultimately leading to valve leakage.