煤气与热力2026,Vol.46Issue(9):1-4,4.
供热管道保温及减阻效果测试分析
Testing and Analysis on Thermal Insulation and Drag-Reduction Performance of Heating Pipelines
杨硕 1冯文亮 2甄浩然 2王松川3
作者信息
- 1. 北京北燃实业集团有限公司,北京 100023
- 2. 北京市公用事业科学研究所有限公司,北京 100011||北京市建设工程质量第四检测所有限公司,北京 100011
- 3. 北京北燃供热有限公司,北京 100023
- 折叠
摘要
Abstract
Taking PE-RT Ⅱ plastic pipelines as the research object,heat loss tests are performed on insu-lated and noninsulated PE-RT Ⅱ plastic pipes to ana-lyze their thermal insulation performance.The equiva-lent roughness of PE-RT Ⅱ pipes is calculated from testing data,and the dragreduction performance is ana-lyzed by comparison with steel pipes.With the same insulation and external protective layer,the overall thermal resistance of the insulation system for PE-RTⅡ pipes is 4.7%higher than that of steel pipes.The polyurethane foam layer is the main guarantee of ther-mal insulation performance for directly buried heating pipelines.Compared with steel pipes,PE-RT Ⅱ plas-tic pipes exhibit increasingly prominent drag-reduction performance as the flow rate rises.关键词
PE-RTⅡ型塑料管/单位管道长度散热量/沿程阻力Key words
PE-RT Ⅱ plastic pipe/heat loss per unit pipe length/frictional resistance分类
建筑与水利引用本文复制引用
杨硕,冯文亮,甄浩然,王松川..供热管道保温及减阻效果测试分析[J].煤气与热力,2026,46(9):1-4,4.