| 注册
首页|期刊导航|南京航空航天大学学报(英文版)|基于RENA-3的粒子探测系统中低耦合电容影响研究

基于RENA-3的粒子探测系统中低耦合电容影响研究

杨芯 叶雨光 王玲华 于向前 施伟红 陈鸿飞 王游龙 王永福 宗秋刚 邹鸿

南京航空航天大学学报(英文版)2026,Vol.43Issue(4):506-516,11.
✕
南京航空航天大学学报(英文版)2026,Vol.43Issue(4):506-516,11.DOI:10.16356/j.1005-1120.2026.04.002

基于RENA-3的粒子探测系统中低耦合电容影响研究

Research on Influence of Low Coupling Capacitance in the RENA-3-Based Particle Detection System

杨芯 1叶雨光 2王玲华 1于向前 1施伟红 2陈鸿飞 2王游龙 2王永福 2宗秋刚 2邹鸿2

作者信息

  • 1. 北京大学地球与空间科学学院空间物理与应用技术研究所,北京 100871,中国||中国科学院国家空间科学中心太阳活动与空间天气国家重点实验室,北京 100190,中国
  • 2. 北京大学地球与空间科学学院空间物理与应用技术研究所,北京 100871,中国
  • 折叠

摘要

Abstract

The performance of a particle detection system is primarily determined by its first stage,which mainly includes a particle radiation detector and a charge-sensitive preamplifier(CSA).The connection between the detector and the front-end readout circuit is typically AC-coupled,which usually has a coupling capacitor in the range of 0.01-0.1 μF to isolate the input of the CSA from the detector.The application-specific integrated circuit(ASIC)readout electronics for nuclear applications 3(RENA-3)is a multi-channel mixed-signal integrated circuit(IC)offering high energy resolution and high time resolution,developed for the readout of particle radiation detectors.RENA-3 is employed as the front-end readout circuit for an interplanetary energetic particle telescope designed to detect 20-1 000 keV electrons,25-12 000 keV protons,and ions like alpha particles.However,the maximum input charge of RENA-3 is 54 fC,which limits its maximum detection range to about 1 200 keV and is insufficient for the proton channels.While other ASICs could be adopted,available alternatives do not simultaneously meet the requirements for both high precision and wide measurement range.This paper proposes the use of a small coupling capacitance to extend the range for proton detection by attenuating the charge signal before it reaches the CSA input.The coupling capacitance is on the order of picofarads,much smaller than the detector junction capacitance.In this configuration,stray capacitance and coupling capacitance become significant.A circuit theoretical model is proposed to calculate the transfer function from input charge to output voltage,analyzing the influence of coupling capacitance and stray capacitance on the particle radiation detection system.Experiments using discrete components with known parameters are conducted to validate the theoretical model.Finally,the model is applied to the RENA-3 system for optimization to meet the instrument's specifications,and certain RENA-3 parameters are derived.

关键词

交流耦合电路/耦合电容/杂散电容/电路表现/粒子辐射探测系统

Key words

AC-coupled circuit/coupling capacitance/stray capacitance/circuit performance/particle radiation detection system

分类

信息技术与安全科学

引用本文复制引用

杨芯,叶雨光,王玲华,于向前,施伟红,陈鸿飞,王游龙,王永福,宗秋刚,邹鸿..基于RENA-3的粒子探测系统中低耦合电容影响研究[J].南京航空航天大学学报(英文版),2026,43(4):506-516,11.

基金项目

This work was supported in part by the National Natural Science Foundation of China under con-tracts(Nos.42127803,42225404,42150105)and the Na-tional Key R&D Program of China(No.2023YFC2808904). (Nos.42127803,42225404,42150105)