| 注册
首页|期刊导航|制冷|大学教室空气质量与空调能耗智能控制策略研究

大学教室空气质量与空调能耗智能控制策略研究

张春阳

制冷2026,Vol.45Issue(4):54-58,81,6.
✕
制冷2026,Vol.45Issue(4):54-58,81,6.DOI:10.3969/J.ISSN.1005-9180.2026.04.0009

大学教室空气质量与空调能耗智能控制策略研究

University Classroom Air Quality and Intelligent Control Strategies for Air Conditioning Energy Consumption

张春阳1

作者信息

  • 1. 郑州升达经贸管理学院,河南郑州,451191
  • 折叠

摘要

Abstract

This study employs ANSYS simulation software to establish and simulate an air conditioning model for a university classroom.Under the premise of ensuring indoor thermal comfort,the simulated temperature and velocity fields are analyzed to optimize the air distribution of the central air conditioning system.Furthermore,an analysis of the carbon dioxide(CO2)concentration field is conducted to provide optimization strategies regarding the supply mode and source of fresh air.The results offer theoretical support for balancing indoor air quality(IAQ)and energy efficiency in educational buildings.

关键词

ansys仿真/空气质量/空调能耗/智能控制

Key words

ANSYS Simulation/Indoor Air Quality/Air Conditioning Energy Consumption/Intelligent Control