电力系统自动化2026,Vol.50Issue(19):213-223,11.DOI:10.7500/AEPS20250320009
基于频带能量比率制动的海上风电直流汇集线路保护
DC Collection Line Protection for Offshore Wind Power Based on Frequency-band Energy Ratio Restraint
摘要
Abstract
Offshore wind power DC collection systems with multiple collection lines and complex topologies face challenges in locating faults on DC collection lines.To address this issue,this paper proposes a single-ended protection method of DC collection lines for offshore wind power based on frequency-band energy ratio restraint.First,equivalent models for single-pole grounding faults and bipolar short-circuit faults are established to analyze the amplitude-frequency characteristics and energy distribution patterns of fault transient signals.Second,complementary ensemble empirical mode decomposition(CEEMD)is employed to perform time-frequency decomposition of fault transient signals.The ratio between dominant frequency energy and DC energy from the decomposed components is utilized to adaptively adjust the setting values of energy integral criterion,enabling faulty line selection.Additionally,the proposed protection method can serve as backup protection for DC busbar.PSCAD simulation results demonstrate that the proposed method achieves rapid and accurate faulty line identification with strong noise immunity and high tolerance to transition resistance.关键词
海上风电场/直流汇集/集合/经验模态分解/故障暂态信号/线路保护/单端保护/后备保护Key words
offshore wind farm/DC collection/ensemble/empirical mode decomposition/fault transient signal/line protection/single-ended protection/backup protection引用本文复制引用
刘晨斐,邹贵彬,魏秀燕..基于频带能量比率制动的海上风电直流汇集线路保护[J].电力系统自动化,2026,50(19):213-223,11.基金项目
山东省自然科学基金资助项目(ZR2024ME009). This work is supported by Shandong Provincial Natural Science Foundation of China(No.ZR2024ME009). (ZR2024ME009)