| 注册
首页|期刊导航|电力系统自动化|含多静止无功发生器的新能源多馈入系统静态电压稳定性分析

含多静止无功发生器的新能源多馈入系统静态电压稳定性分析

胡茂琳 袁辉 娄云天 辛焕海

电力系统自动化2026,Vol.50Issue(20):90-98,9.
✕
电力系统自动化2026,Vol.50Issue(20):90-98,9.DOI:10.7500/AEPS20250830005

含多静止无功发生器的新能源多馈入系统静态电压稳定性分析

Static Voltage Stability Analysis of Multi-infeed Systems with Renewable Energy and Multiple Static Var Generators

胡茂琳 1袁辉 2娄云天 3辛焕海4

作者信息

  • 1. 浙江大学工程师学院,浙江省 杭州市 310027
  • 2. 广西大学电气工程学院,广西壮族自治区 南宁市 530004
  • 3. 浙江大学电气工程学院,浙江省 杭州市 310027
  • 4. 浙江大学电气工程学院,浙江省 杭州市 310027||全省可再生能源电气技术与系统重点实验室,浙江省 杭州市 310027
  • 折叠

摘要

Abstract

To enhance the voltage support capability of renewable energy bases,grid codes require that a certain proportion of static var generators(SVGs)should be installed in these bases.However,how SVGs affect the static voltage stability of renewable energy bases remains unclear.To address this issue,a static voltage stability analysis method for multi-infeed systems with renewable energy and multiple SVGs is proposed.Firstly,the power flow Jacobian matrix and characteristic equation of the multi-infeed system with multiple SVGs are derived,suitable for static voltage stability analysis.Secondly,under certain assumptions,it is proved that the static voltage stability analysis of the original multi-infeed system can be simplified to analyzing the static voltage stability of the weakest characteristic subsystem,and it is demonstrated that the generalized short-circuit ratio(gSCR)is applicable to the static voltage stability analysis of multi-infeed systems with multiple SVGs.On this basis,two sufficient conditions for static voltage stability of the system in the constant reactive power control mode of multiple SVGs are provided.Finally,it is shown that when SVGs adopt the constant AC voltage control mode,the improvement in system static voltage stability is superior to that in the constant reactive power control mode.Simulation results verify the theoretical analysis and the correctness of the proposed static voltage stability analysis method.

关键词

新能源/多馈入系统/静止无功发生器/广义短路比/静态电压/稳定性/系统强度

Key words

renewable energy/multi-infeed system/static var generator(SVG)/generalized short-circuit ratio(gSCR)/static voltage/stability/system strength

引用本文复制引用

胡茂琳,袁辉,娄云天,辛焕海..含多静止无功发生器的新能源多馈入系统静态电压稳定性分析[J].电力系统自动化,2026,50(20):90-98,9.

基金项目

国家重点研发计划资助项目(2023YFB2405900) (2023YFB2405900)

国家自然科学基金资助项目(52207140) (52207140)

浙江省自然科学基金资助项目(LY23E070003). This work is supported by National Key R&D Program of China(No.2023YFB2405900),National Natural Science Foundation of China(No.52207140),and Zhejiang Provincial Natural Science Foundation of China(No.LY23E070003). (LY23E070003)