| 注册
首页|期刊导航|计量学报|光源强度对荧光光纤温度计精度的影响及自调节方法研究

光源强度对荧光光纤温度计精度的影响及自调节方法研究

路宗敏 关卫军 邵飞 周艺 张禹 赵洪波

计量学报2026,Vol.47Issue(9):1279-1284,6.
✕
计量学报2026,Vol.47Issue(9):1279-1284,6.DOI:10.3969/j.issn.1000-1158.2026.09.05

光源强度对荧光光纤温度计精度的影响及自调节方法研究

Effects of Excitation Light Intensity on Accuracy of Fluorescent Fiber Optic Thermometers and Auto-adjustment Mechanism Study

路宗敏 1关卫军 1邵飞 2周艺 1张禹 1赵洪波2

作者信息

  • 1. 陕西省计量科学研究院,陕西 西安 710100
  • 2. 西安和其光电科技股份有限公司,陕西 西安 710199
  • 折叠

摘要

Abstract

The medical and semiconductor industries impose stringent accuracy requirements on fluorescent fiber optic thermometers,research on improving the temperature measurement accuracy of fluorescent fiber optic thermometers is attracting significant attention.In order to investigate the impact of excitation light source intensity variations on thermometer accuracy,a theoretical analysis was conducted based on the operating principle of fluorescent fiber optic thermometers,and experiments were designed to evaluate the influence of excitation currents(1,2,3,4,5,6,7,and 8 mA)on fluorescence lifetime measurements at 0,50,and 100℃.The experimental results showed that when the excitation current was within the range of 1~4 mA,the fluorescence lifetime exhibited minor fluctuations.However,when the excitation current increased from 4 mA to 8 mA,the fluorescence lifetime significantly increased by more than 10%.Analysis of fluorescence intensity decay curves under varying excitation intensities demonstrated that excessive light intensity causes detector saturation,resulting in incomplete capture of decay profiles.By leveraging the linear relationship between excitation light intensity and fluorescence intensity,an automatic adjustment mechanism for excitation light intensity was established.This innovation enabled acquisition of complete fluorescence decay curves,and the temperature measurement accuracy of fluorescent fiber optic thermometers was improved effectively.

关键词

温度测量/荧光光纤温度计/激发光源/测温精度/自调节机制

Key words

temperature measurement/fluorescent fiber optic thermometer/excitation light source/temperature measurement accuracy/automatic intensity adjustment mechanism

分类

通用工业技术

引用本文复制引用

路宗敏,关卫军,邵飞,周艺,张禹,赵洪波..光源强度对荧光光纤温度计精度的影响及自调节方法研究[J].计量学报,2026,47(9):1279-1284,6.

基金项目

陕西省重点研发计划(2024GX-YBXM-203) (2024GX-YBXM-203)