北京大学学报(医学版)2026,Vol.58Issue(5):940-949,10.DOI:10.19723/j.issn.1671-167X.2026.05.007
传统工艺和CAD/CAM一体式切削全口义齿短期临床效果的自身对照
Short-term clinical outcomes of complete dentures fabricated by conventional and CAD/CAM milling techniques:A self-controlled study with randomized wearing se-quence
摘要
Abstract
Objective:To preliminarily compare the short-term clinical outcomes of conventional and computer-aided design/computer-aided manufacturing(CAD/CAM)monolithic milled complete dentures and to provide clinical evidence for selecting a digital complete-denture fabrication technique.Methods:Seven edentulous patients were enrolled in a self-controlled study with a randomized wearing sequence.Each participant received one conventionally fabricated complete denture and one CAD/CAM monolithic milled complete denture.The fabrication technique was not actively disclosed before subjective assess-ment.A 2-week washout period,during which the participants wore their previous dentures,separated the two wearing periods.Subjective visual analogue scale(VAS)scores for overall satisfaction,mandibu-lar denture retention,masticatory function,mucosal comfort,speech,and esthetics,together with pressure-point count,objective mandibular retention force,and objective masticatory efficiency,were as-sessed at insertion,1 week,and 1 month.Within-patient comparisons between the two techniques were performed at each time point.Overall satisfaction,pressure-point count,objective retention force,and objective masticatory efficiency were additionally analyzed using a 2 × 3 fully within-subject repeated-measures analysis of variance(ANOVA),followed by Bonferroni-adjusted post hoc comparisons.Re-sults:Significant between-process differences in satisfaction,aesthetics,retention VAS,mastication VAS,and pressure point counts were found over three time points(all P<0.05),favoring CAD/CAM milling.No significant between-group difference in phonation.CAD/CAM milling yielded higher mandibular retention force at insertion,1 week,and 1 month(P<0.001,P=0.004,and P<0.001,respectively).Objective masticatory efficiency was 38.53%±3.75%versus 42.73%±3.67%at inser-tion(P=0.057),45.09%±3.89%versus 52.93%±2.60%at 1 week(P=0.001),and 52.22%±3.88%versus 56.69%±3.28%at 1 month(P=0.031)for the conventional and CAD/CAM groups,respectively.Repeated-measures ANOVA revealed significant technique and time effects for all four variables.A significant technique × time interaction was identified only for pressure-point count[F(2,12)=5.550,P=0.020];the interaction for objective mandibular retention force was not signifi-cant after Greenhouse-Geisser correction[F(1.090,6.540)=2.547,P=0.162].Conclusion:In this small,short-term,within-patient study with a randomized wearing sequence,CAD/CAM monolithic milled complete dentures showed advantages in several patient-reported outcomes,objective mandibular retention force,and objective masticatory efficiency at 1 week and 1 month.These advantages did not extend to all outcomes or time points,and the between-technique difference in pressure-point count narrowed over time.关键词
全口义齿/CAD/CAM/数字化修复/自身对照研究Key words
Complete denture/Computer-aided design/computer-aided manufacturing(CAD/CAM)/Digital prosthodontics/Self-controlled study分类
医药卫生引用本文复制引用
曹慧,秦凯启,张旭,陈虎,孙玉春,包雪梅,周永胜..传统工艺和CAD/CAM一体式切削全口义齿短期临床效果的自身对照[J].北京大学学报(医学版),2026,58(5):940-949,10.基金项目
国家重点研发计划项目(2023YFB4605400)和国家自然科学基金(82530030)Supported by the National Key R&D Program of China(2023YFB4605400)and the National Natural Science Foundation of China(82530030) (2023YFB4605400)