| 注册
首页|期刊导航|岩土力学|含预制裂缝的大尺度人工岩样注采换热试验研究

含预制裂缝的大尺度人工岩样注采换热试验研究

李宗泽 魏春雷 杨梓瑞 朱海燕 宇波 汪道兵 王跃社

岩土力学2026,Vol.47Issue(10):3381-3388,8.
✕
岩土力学2026,Vol.47Issue(10):3381-3388,8.DOI:10.16285/j.rsm.2025.1137

含预制裂缝的大尺度人工岩样注采换热试验研究

Experimental investigation on heat transfer during injection-extraction processes in large-scale artificial rock specimens containing prefabricated fractures

李宗泽 1魏春雷 2杨梓瑞 2朱海燕 3宇波 4汪道兵 5王跃社1

作者信息

  • 1. 西安交通大学 动力工程多相流国家重点实验室,陕西 西安 710049
  • 2. 北京石油化工学院 机械工程学院,北京 102617
  • 3. 成都理工大学 油气藏地质及开发工程全国重点实验室,四川 成都 610059||成都理工大学 能源学院,四川 成都 610059
  • 4. 长江大学 石油工程学院,湖北 武汉 430100
  • 5. 北京石油化工学院 机械工程学院,北京 102617||北京市安全生产工程技术研究院,北京 102617||北京石油化工学院 地热高效开发与智慧供能北京市重点实验室,北京 102617
  • 折叠

摘要

Abstract

Hot dry rock(HDR)is a major carrier of deep geothermal energy,characterized by its vast reserves,extensive geographical distribution,and low-carbon clean attributes.It represents a key direction for renewable energy development under the framework of the dual carbon goals.To investigate the impact of complex fracture structures and injection-extraction schemes on the heat extraction efficiency of HDR reservoirs,this study developed a large-scale artificial rock sample with prefabricated fractures and established a thermo-hydro-mechanical(THM)coupled injection-extraction heat exchange experimental system.Fracture frameworks were constructed using paper and proppant particles,and artificial rock samples measuring 400 mm×400 mm×400 mm were fabricated through a mold casting technique.A series of heat exchange experiments was systematically executed under varying combinations of fracture geometries(long straight fracture,deflected fracture,branched fracture)and injection-extraction schemes(single injection-single extraction,single injection-dual extraction).The experimental outcomes indicate that fracture geometry exerts a limited effect on the temperature field,whereas seepage flow plays a predominant role.The injection-extraction scheme significantly affects heat exchange performance;when the injection rate escalates from 11 mL/min to 50 mL/min,the cooling rate of the produced fluid rises from 0.6 ℃/10 min to 10.2 ℃/10 min.This study reveals the critical roles of flow distribution and the stability of seepage pathways in short-term heat extraction capacity,providing experimental evidence and theoretical support for fracture design and optimization of injection-extraction parameters in enhanced geothermal system(EGS).

关键词

干热岩/增强型地热系统/预制裂缝/注采试验/渗流能力/采热效率

Key words

hot dry rock(HDR)/enhanced geothermal system(EGS)/prefabricated fractures/injection-extraction experiment/seepage capacity/heat extraction efficiency

分类

建筑与水利

引用本文复制引用

李宗泽,魏春雷,杨梓瑞,朱海燕,宇波,汪道兵,王跃社..含预制裂缝的大尺度人工岩样注采换热试验研究[J].岩土力学,2026,47(10):3381-3388,8.

基金项目

国家自然科学基金(No.52274002,No.52474001,No.52192622) (No.52274002,No.52474001,No.52192622)

国家重点研发计划(No.2024YFF0505802). This work was supported by the National Natural Science Foundation of China(52274002,52474001,52192622)and the National Key R&D Program of China(2024YFF0505802). (No.2024YFF0505802)