Objective: To establish a determination method of cadmium in peanuts by inductively coupled plasma-mass spectroscopy (ICP-MS) and evaluate the uncertainty of determination results. Methods: A mathematic model was established by analyzing the uncertainty sources from different parts. The final uncertainty degree was calculated by standard uncertainty and extended uncertainty during measurements. Results: The cadmium content in peanuts was determined to be (162 ± 5) μ g/ kg with a k value of 2, which met the national standard. The major uncertainty was attributed to four sources such as repeatability of measurement, calibration of standard solution, volume and sampling. Conclusion: This method is applicable to the evaluation of uncertainty during component determination in foods by ICP-MS.

关键词

电感耦合等离子体质谱仪//不确定度/花生/校准

Key words

inductively coupled plasma-mass spectroscopy (ICP-MS): cadmium/uncertainty evaluation/peanut/calibration