| 注册
首页|期刊导航|CT理论与应用研究|双源CT峰值跟踪法颈部CTA扫描优化方案初步探讨

双源CT峰值跟踪法颈部CTA扫描优化方案初步探讨

陈新 周长圣 张军 顾海峰 罗松 郑玲

CT理论与应用研究2011,Vol.20Issue(4):537-544,8.
CT理论与应用研究2011,Vol.20Issue(4):537-544,8.

双源CT峰值跟踪法颈部CTA扫描优化方案初步探讨

Research of DSCT Neck CTA Optimizing Program

陈新 1周长圣 1张军 1顾海峰 1罗松 1郑玲1

作者信息

  • 1. 南京军区南京总医院医学影像科,南京210002
  • 折叠

摘要

Abstract

Objective: To explore optimal program of dual-source CT in cervical vessel. Methods: 60 Neck CTA cases were randomly divided into two groups (A and B, each group contains 30 cases). The injection rate of contrast is 4.0 mL/s. With the help of automatic trigger technic taking triggered threshold as 120 Hu scanning began4 seconds after the CT value arriving at the peak 75 Hu peak While scanning direction was from caudal to cranial in A group, and cranial to caudal in group B, which is the optimal program. The other parameters were constant. All data was sent to the workstation and evaluated by SIEMENS software. Results: The CT value of brachiocephalic veininjected between group A and B had statistical significance (p 〈 0.01). Although the CT value of aortic artery in group B was a bit higher than that in group A, and the CT value of middle cerebral artery in group B was a bit lower than that in group A, those had no statistical significance. Conclusion: The optimal program of dual-source CT in cervical vessel can effectively demolish the disturbance of brachiocephalic vein injected and improve the image quality of cervical artery.

关键词

CT血管成像/X线计算机/颈动脉

Key words

CT angiography/X-ray computed/carotid artery

分类

医药卫生

引用本文复制引用

陈新,周长圣,张军,顾海峰,罗松,郑玲..双源CT峰值跟踪法颈部CTA扫描优化方案初步探讨[J].CT理论与应用研究,2011,20(4):537-544,8.

CT理论与应用研究

OACSTPCD

1004-4140

访问量0
|
下载量0
段落导航相关论文