Abstract

[Objective] To establish an effective and reliable method to determine whether copper content in drinking water is excessive. [Method] Copper content in water was determined with flame atomic absorption method, and the uncertainty was analyzed, lResult] The concentration of copper in water samples was 0. 232μg/mL, and expanded uncertainty of measurement results was U =0. 07μ g/mL and k = 2. [Conclusion] This method was fast and accurate to determine copper content in water. Measurement results were in line with GB5749- 2006 Sanitary Standard for Drinking Water.

关键词

原子吸收法//不确定度

Key words

atomic absorption spectrophotometer/copper/uncertainty

分类

建筑与水利

引用本文复制引用

刘嘉祺,孙仁国..原子吸收法测定水中铜含量及测量结果的不确定度分析[J].中国食物与营养,2012,18(8):16-18,3.