| 注册
首页|期刊导航|食品工业科技|副溶血弧菌的磁珠捕获及检测

副溶血弧菌的磁珠捕获及检测

王报贵 武晓丽 董素琴 陈飞 陈星星 甘敏 明星 徐锋

食品工业科技2013,Vol.34Issue(13):147-152,6.
食品工业科技2013,Vol.34Issue(13):147-152,6.

副溶血弧菌的磁珠捕获及检测

Bead capture and detection of Vibrio parahaemolyticus

王报贵 1武晓丽 2董素琴 1陈飞 1陈星星 1甘敏 1明星 1徐锋1

作者信息

  • 1. 南昌大学生命科学与食品工程学院中德联合研究院,江西南昌330047
  • 2. 江西中医学院基础医学部,江西南昌330004
  • 折叠

摘要

Abstract

A novel method was developed for rapid detection of Vibrio parahaemolyticus with immunomagnetic separation followed by PCR.Whole cells of V.parahaemolyticus were used as antigen for polyclonal antibody(pAb)production in rabbit.Titers of pAb were detected by enzyme-linked immunosorbent assay(ELISA).Antiserum was purified with ammonium sulfate precipitation and reverse adsorption,purity and specificity of the resulted pAb was tested with SDS-PAGE and dot-blot hybridization.Purified pAb was conjugated with magnetic beads for bacteria separation.Results showed that the titer of purified antibody was 106,and the capture rates of immunomagnetic beads were between 55%~70% under different conditions.Salt concentration and pH had only slight influence on the capture rate.The limit of detection(LOD) of the method was 102cfu/mL in pure culture and 103cfu/mL in fish paste samples (in presence of other kinds of bacteria species).In conclusion,combined immunomagnetic separation with PCR for the detection of V.parahaemolyticus has high sensitivity and specificity,which is promising for in-field detection.

关键词

副溶血弧菌/多克隆抗体/免疫磁珠/PCR

Key words

Vibrio parahaemolyticus/ polyclonal antibodies/ immunomagnetic beads/ PCR

分类

轻工纺织

引用本文复制引用

王报贵,武晓丽,董素琴,陈飞,陈星星,甘敏,明星,徐锋..副溶血弧菌的磁珠捕获及检测[J].食品工业科技,2013,34(13):147-152,6.

基金项目

"十二五"国家科技支撑计划(2011BAK10B06,2011BAK10B01,2011BAK10B02) (2011BAK10B06,2011BAK10B01,2011BAK10B02)

国家自然科学基金项目(3100008,31170091) (3100008,31170091)

食品科学与技术国家重点实验室目标导向课题(SKLF-MB-201002)、自由探索课题(SKLF-TS-200916) (SKLF-MB-201002)

2012年赣鄱英才555工程人才计划. ()